Etude expérimentale du dimensionnement des étages pour des réfrigérateurs à tube pulsé à deux étages fonctionnant à la température de l'hélium liquide.

Experimental study of staging method for two-stage pulse tube refrigerators for liquid helium-4 temperatures.

Auteurs : WANG C., THUMMES G., HEIDEN C.

Type d'article : Article

Résumé

Three modified staging methods were tested in the paper. All refrigerator versions operate with the same two regenerators as already used in the first two-stage setup and also the same 6-kilowatt helium-compressor combined with a redesigned Gifford-McMahon rotary valve. The best performance is achieved with a parallel arrangement two-stage refrigerator by introducing proper negative direct-current flow and impedance tubes. Details of the design of the different refrigerators and a comparison of their performance are presented.

Détails

  • Titre original : Experimental study of staging method for two-stage pulse tube refrigerators for liquid helium-4 temperatures.
  • Identifiant de la fiche : 1998-2653
  • Langues : Anglais
  • Source : Cryogenics - vol. 37 - n. 12
  • Date d'édition : 12/1997

Liens


Voir d'autres articles du même numéro (5)
Voir la source