Experimental study of staging method for two-stage pulse tube refrigerators for liquid helium-4 temperatures.
Author(s) : WANG C., THUMMES G., HEIDEN C.
Type of article: Article
Summary
Three modified staging methods were tested in the paper. All refrigerator versions operate with the same two regenerators as already used in the first two-stage setup and also the same 6-kilowatt helium-compressor combined with a redesigned Gifford-McMahon rotary valve. The best performance is achieved with a parallel arrangement two-stage refrigerator by introducing proper negative direct-current flow and impedance tubes. Details of the design of the different refrigerators and a comparison of their performance are presented.
Details
- Original title: Experimental study of staging method for two-stage pulse tube refrigerators for liquid helium-4 temperatures.
- Record ID : 1998-2653
- Languages: English
- Source: Cryogenics - vol. 37 - n. 12
- Publication date: 1997/12
Links
See other articles in this issue (5)
See the source
Indexing
-
On the numerical design of a new type of 4 K GM...
- Author(s) : JU Y. L., WANG L.
- Date : 2002/09
- Languages : English
- Source: Cryogenics - vol. 42 - n. 9
View record
-
Generation of liquid helium temperatures using ...
- Author(s) : SCHNEIDEMESSER A. von, THUMMES G., HEIDEN C.
- Date : 2000/01
- Languages : English
- Source: Cryogenics - vol. 40 - n. 1
View record
-
Helium liquefaction with a commercial 4 K Giffo...
- Author(s) : SCHMIDT-WELLENBURG P., ZIMMER O.
- Date : 2006/11
- Languages : English
- Source: Cryogenics - vol. 46 - n. 11
View record
-
STABLE 4 K CRYOCOOLER USING CYCLED ADIABATIC (S...
- Author(s) : WINTER C.
- Date : 1985
- Languages : English
- Source: Cryogenics - vol. 25 - n. 2
View record
-
Pulsröhrenkühler zur Erzeugung von Temperaturen...
- Author(s) : THUMMES G., WANG C., BENDER S., HEIDEN C.
- Date : 1996/11/20
- Languages : German
- Source: DKV-Tagungsbericht 23. 1996 Leipzig.
View record