Document IIF

Étude expérimentale du frigorigène à faible GWP R446A comme alternative au R410A dans un conditionneur d'air résidentiel.

Experimental studying on low GWP refrigerant R446A as an alternative to R410A in residential air conditioner.

Numéro : pap. n. 680

Auteurs : LIN E., NIU Y., HUO H., et al.

Résumé

New low global warming potential refrigerant R446A was developed to replace R410A in residential air conditioner. Theory cycle analysis shows that 10% more displacement compressor was recommended for R446A comparing with R410A. The compressor evaluation shows that R446A was similar to that of R410A, and the COP of R446A was higher than that of R410A when the 10% more displacement compressor was used for R446A.The air conditioner evaluation shows that: the capacity of R446A was similar to that of R410A, the COP was higher than that of R410A when the 10% more displacement compressor was adopted for R446 and control algorithm was optimized. R446A was an alternative refrigerant to R410A used in the residential air conditioner.

Documents disponibles

Format PDF

Pages : 8 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental studying on low GWP refrigerant R446A as an alternative to R410A in residential air conditioner.
  • Identifiant de la fiche : 30015585
  • Langues : Anglais
  • Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Date d'édition : 16/08/2015
  • DOI : http://dx.doi.org/10.18462/iir.icr.2015.0680

Liens


Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence