IIR document

Experimental studying on low GWP refrigerant R446A as an alternative to R410A in residential air conditioner.

Number: pap. n. 680

Author(s) : LIN E., NIU Y., HUO H., et al.

Summary

New low global warming potential refrigerant R446A was developed to replace R410A in residential air conditioner. Theory cycle analysis shows that 10% more displacement compressor was recommended for R446A comparing with R410A. The compressor evaluation shows that R446A was similar to that of R410A, and the COP of R446A was higher than that of R410A when the 10% more displacement compressor was used for R446A.The air conditioner evaluation shows that: the capacity of R446A was similar to that of R410A, the COP was higher than that of R410A when the 10% more displacement compressor was adopted for R446 and control algorithm was optimized. R446A was an alternative refrigerant to R410A used in the residential air conditioner.

Available documents

Format PDF

Pages: 8 p.

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental studying on low GWP refrigerant R446A as an alternative to R410A in residential air conditioner.
  • Record ID : 30015585
  • Languages: English
  • Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
  • Publication date: 2015/08/16
  • DOI: http://dx.doi.org/10.18462/iir.icr.2015.0680