Étude expérimentale et numérique de la détérioration du condenseur alimenté par ventilateur et de la performance correspondante du réfrigérateur en configuration encastrée.
Experimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance.
Résumé
The built-in refrigerator has been popular in China in recent years due to users’ high requirements for the integration of home appliances and furnishings. However, the built-in configuration will cause a significant performance deterioration, which has been less quantitively studied. The condenser and its refrigerator performance are compared experimentally and numerically between built-in and free-standing configurations. By contrast with the free-standing condition, the built-in condenser has poor performance attributed to two reasons: 28.6% lower condenser air flowrate and 10.72 °C higher condenser inlet air temperature caused by the hot short-circuited airflow. This heat dissipation deterioration increases the condensing temperature and discharge temperature, resulting in a refrigerator cooling capacity loss. Correspondingly, the compressor increases the rotating speed and power to compensate for the loss. The compressor ON-time ratio reduces by 8% but the average power during the compressor-on period increases by 56.9%, finally increasing the energy consumption by 43.4%. This study also provides some guidance for further heat dissipation and airflow field optimization of built-in refrigerators.
Documents disponibles
Format PDF
Pages : 14 p.
Disponible
Gratuit
Détails
- Titre original : Experimental and Numerical Study on Fan-Supplied Condenser Deterioration under Built-In Condition and Its Corresponding Refrigerator Performance.
- Identifiant de la fiche : 30030951
- Langues : Anglais
- Sujet : Technologie
- Source : Energies - vol. 15 - n. 22
- Éditeurs : MDPI
- Date d'édition : 11/2022
- DOI : http://dx.doi.org/https://doi.org/10.3390/en15228666
Liens
Voir d'autres articles du même numéro (13)
Voir la source
Indexation
-
Improving energy efficiency of built-in refrige...
- Auteurs : GEPPERT J., STAMMINGER R.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche
-
Theoretical and experimental evaluation of micr...
- Auteurs : RAMETTA R. S., BOENG J., MELO C.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Improved airside modeling of heat exchangers fo...
- Auteurs : WIMMER K.
- Date : 10/07/2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental investigation and numerical optimi...
- Auteurs : GHOLAP A. K., KHAN J. A., HUANG Z.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Impact of aging on the energy efficiency of hou...
- Auteurs : PAUL A., BAUMHÖGGER E., ELSNER A., REINEKE M., HUEPPE C., STAMMINGER R., HOELSCHER H., WAGNER H., GRIES U., BECKER W., VRABEC J.
- Date : 03/2022
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 205
Voir la fiche