Étude expérimentale et numérique des refroidisseurs évaporatifs indirects au point de rosée pour optimiser les performances et la conception.
Experimental and numerical study of dew-point indirect evaporative coolers to optimize performance and design.
Auteurs : COMINO F., ROMERO-LARA M. J., RUIZ DE ADANA M.
Type d'article : Article de la RIF
Résumé
Dew-point indirect evaporative coolers (DIEC) allow to significantly reduce air temperature from supply air flow and require a low energy consumption, so they could be an interesting alternative to conventional air-cooling system. In the present work, the optimal geometric design and the optimal operational parameters of DIEC systems to achieve cooling conditions and comply with the European ventilation regulations were determined. Hence, the experimental energy performance of a DIEC under different inlet air conditions was studied, and a detailed DIEC model based on the ε-NTU method was developed and validated. The experimental results showed very high DIEC dew-point effectiveness values, up to 0.87. Additionally, the numerical results obtained with the detailed DIEC model were in very good agreement with the experimental results, so this model can be adequately used to analyse and optimise DIEC systems. The optimal geometric designs and operational parameters of the DIEC systems depended on the type of space to be conditioned and the ventilation category. The maximum COP values were always obtained for low values of volumetric air flow rate, 50.26 for an office application, 44.19 for the restaurant application and 37.14 for the auditorium application. However, the highest compactness of the DIEC designs were achieved for medium and high values of volumetric air flow rate ratio, between 0.45 and 0.8. The results obtained could significantly help to achieve the objectives of sustainable cooling and ventilation of spaces in the frame of Nearly Zero Energy Buildings.
Documents disponibles
Format PDF
Pages : 92-102
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental and numerical study of dew-point indirect evaporative coolers to optimize performance and design.
- Identifiant de la fiche : 30030203
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 142
- Date d'édition : 10/2022
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.06.006
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (14)
Voir la source
Indexation
-
Performance analysis of a thermoelectric assist...
- Auteurs : GAO M., ZHOU Y., YU J., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Experimental Study on the Performance of a Dew-...
- Auteurs : LV J., ZHOU B., ZHU M., XI W., HU E.
- Date : 04/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 7
- Formats : PDF
Voir la fiche
-
Machine learning model of regenerative evaporat...
- Auteurs : GUPTA A. K., KASHYAP S., SARKAR J.
- Date : 05/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 137
- Formats : PDF
Voir la fiche
-
Studying the performance of an improved dew-poi...
- Auteurs : CUI X., CHUA K. J., YANG W. M., et al.
- Date : 02/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 63 - n. 2
Voir la fiche
-
Comparison of 1D and 3D heat and mass transfer ...
- Auteurs : PAKARI A., GHANI S.
- Date : 03/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 99
- Formats : PDF
Voir la fiche