Document IIF
Étude comparative numérique et expérimentale de modèles de transfert de chaleur et de masse 1D et 3D d’un système de refroidissement évaporatif à point de rosée à contre-courant.
Comparison of 1D and 3D heat and mass transfer models of a counter flow dew point evaporative cooling system: Numerical and experimental study.
Résumé
In this study, the performance of a counter flow dew point evaporative cooling system has been examined, numerically and experimentally. A one-dimensional (1D) model of the heat and mass transfer in the cooling system is presented. In order to assess the 1D model, a detailed three-dimensional (3D) model is developed. Experimental results showed that the wet-bulb effectiveness of the cooling system could reach values as high as 125%. The predicted variations of air temperature along the channels of the cooling system by both models are in fair agreement. On average, the 1D model predicts lower outlet temperatures by about 1.86% relative to the 3D model. While the computational time of the 3D model is about three orders of magnitude higher than the 1D model. The predicted outlet temperature of the cooling system by the 1D and 3D models match the experimental results within 10% and 8.5%, respectively.
Documents disponibles
Format PDF
Pages : 114-125
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of 1D and 3D heat and mass transfer models of a counter flow dew point evaporative cooling system: Numerical and experimental study.
- Identifiant de la fiche : 30025492
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 99
- Date d'édition : 03/2019
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2019.01.013
Liens
Voir d'autres articles du même numéro (45)
Voir la source
-
Experimental Study on the Performance of a Dew-...
- Auteurs : LV J., ZHOU B., ZHU M., XI W., HU E.
- Date : 04/2022
- Langues : Anglais
- Source : Energies - vol. 15 - n. 7
- Formats : PDF
Voir la fiche
-
A numerical model for a dew-point counter-flow ...
- Auteurs : JAFARIAN H., SAYYAADI H., TORABI F.
- Date : 12/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 84
- Formats : PDF
Voir la fiche
-
Performance analysis of a thermoelectric assist...
- Auteurs : GAO M., ZHOU Y., YU J., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Experimental and numerical study of dew-point i...
- Auteurs : COMINO F., ROMERO-LARA M. J., RUIZ DE ADANA M.
- Date : 10/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 142
- Formats : PDF
Voir la fiche
-
Parameters affecting the performance of a dewpo...
- Auteurs : JANSSEN M., UGES P.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche