Document IIF
Etude expérimentale sur l'effet de la longueur du mélangeur sur la performance d'un éjecteur diphasique d'un cycle frigorifique au CO2 avec ou sans échangeur.
Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger.
Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
Type d'article : Article, Article de la RIF
Résumé
In ejector systems using the promising natural refrigerant CO2, the mixing of high-speed two-phase primary flow and suction vapor is crucial in designing an efficient ejector. In this study, the effect of mixing length on ejector system performance was analyzed experimentally. The mixing lengths used were 5, 15, and 25 mm, with constant rectangular cross-section. The experiments were performed for both ejector and conventional expansion systems with and without internal heat exchanger (IHX) at different operating conditions. Based on the experimental results, mixing length had significant effect on entrainment ratio and on magnitude and profile of pressure recovery. The 5 mm and 15 mm types yielded the lowest and highest ejector efficiency and COP in all of the conditions used in this research, respectively. The use of IHX had net positive effect on system performance which verified the results of the authors' previous study. A COP improvement of up to 26% over conventional system was obtained but improper sizing of mixing length lowered the COP by as much as 10%.
Documents disponibles
Format PDF
Pages : 1604-1613
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the effect of mixing length on the performance of two-phase ejector for CO2 refrigeration cycle with and without heat exchanger.
- Identifiant de la fiche : 30001659
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 7
- Date d'édition : 11/2011
Liens
Voir d'autres articles du même numéro (18)
Voir la source
Indexation
-
Efficiency enhancement of vapour compression re...
- Auteurs : JEONG J., SAITO K., KAWAI S.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Investigations of two-phase ejector operating w...
- Auteurs : SMIERCIEW K., BUTRYMOWICZ D., BAJ P., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Investigación en laboratorio de diferentes geom...
- Auteurs : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 09/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 439
- Formats : PDF
Voir la fiche
-
Experimental investigation of different ejector...
- Auteurs : HAFNER A., LADAM Y., ANDRESEN T., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Regeneration of expansion energy by ejector in ...
- Auteurs : OZAKI Y., TAKEUCHI H., HIRATA T.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF