Etude expérimentale sur l'encrassement par des particules dans des échangeurs de chaleur à tubes ailetés dans les appareils de conditionnement d'air.
An experimental study of the air-side particulate fouling in the fin-and-tube heat exchangers of air conditioners.
Auteurs : AHN Y. C., KIM G. T., HWANG Y. J., et al.
Résumé
An experimental study was conducted to investigate the chronological performance variation such as pressure drop across a heat exchanger and cooling capacity due to the air-side particulate fouling of fin-and-tube heat exchangers for air conditioner evaporators used. 30 samples of air conditioners used in the field such as hotels, restaurants, and offices were collected in chronologically used order. The study was intended to provide factual long-term fouling data under actual operating conditions. It was found that the important parameters to influence the fouling of heat exchangers are the concentration and size of indoor pollutants, the filter efficiency, the hydrophilicity of fin surfaces, fin spacing and the structure of fins. The pressure drop of heat exchangers increases from year to year due to the deposition of indoor pollutants larger than 1 m in size and increases up to 44% in the samples used for 7 years. Also, the air-side particulate fouling degraded the cooling capacity by 10-15% in the samples used for 7 years.
Détails
- Titre original : An experimental study of the air-side particulate fouling in the fin-and-tube heat exchangers of air conditioners.
- Identifiant de la fiche : 2007-0635
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
- Date d'édition : 21/05/2006
Liens
Voir d'autres communications du même compte rendu (161)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Autres équipements de conditionnement d'air;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité - Mots-clés : Géometrie; Tube ailette; Mesure; Conditionneur d'air; Refroidisseur d'air; Air; Experimentation; Conditionnement d'air; Échangeur de chaleur; Chute de pression
-
An experimental study of the air-side particula...
- Auteurs : AHN Y. C., CHEONG S. I., JUNG Y. M., et al.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Numerical simulation of dehumidifying fin-and-t...
- Auteurs : OLIET C., PÉREZ-SEGARRA C. D., DANOV S., et al.
- Date : 11/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 7
- Formats : PDF
Voir la fiche
-
Air-side performance evaluation of three types ...
- Auteurs : ZHANG P., HRNJAK P. S.
- Date : 08/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 5
- Formats : PDF
Voir la fiche
-
An experimental study of louver-, wavy- and pla...
- Auteurs : ZHONG Y. F., XIA Y. P., JACOBI A. M.
- Date : 21/08/2007
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
Voir la fiche
-
Echangeurs de chaleur pour conditionneurs d'air.
- Auteurs : SHIKAZONO N.
- Date : 09/2000
- Langues : Japonais
- Source : Refrigeration - vol. 75 - n. 875
Voir la fiche