Document IIF
Etude expérimentale sur la distribution de l'écoulement du frigorigène dans un condenseur à passages multiples sous l'effet de la gravité.
Experimental study of the gravity effect on the distribution of refrigerant flow in a multi-pass condenser.
Résumé
Gravity in multi-pass condensers affects the refrigerant flow rate distribution, owing to the gravitational pressure drop that occurs mainly in the U-bend tubes in fin and tube condensers with horizontal tubes. This effect was studied using an experimental approach. A condenser with two 'nU' circuits was selected, and the temperature variation of the refrigerant side was measured and compared along each circuit. The critical air velocity, which indicated the initiation of the gravity effect, was found for a given refrigerant flow rate. As the air velocity increased beyond the critical air velocity, the gravity effect (or mal-distribution of the refrigerant flow) developed further. Similarly, the critical refrigerant flow rate was also determined for a given air velocity. As the refrigerant flow rate decreased below the critical refrigerant flow rate, the gravity effect also developed further. The gravity-affected region was shown in a table with rows of air velocities and columns of refrigerant flow rates, and expressed using a single parameter for a given refrigerant flow circuit.
Documents disponibles
Format PDF
Pages : 993-1002
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study of the gravity effect on the distribution of refrigerant flow in a multi-pass condenser.
- Identifiant de la fiche : 2005-0689
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 27 - n. 8
- Date d'édition : 12/2004
Liens
Voir d'autres articles du même numéro (21)
Voir la source
Indexation
-
Studies on the flow-induced noise at the evapor...
- Auteurs : CELIK S., NSOFOR E. C.
- Date : 10/2011
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 31 - n. 14-15
Voir la fiche
-
Simulation of air-to-refrigerant fin-and-tube h...
- Auteurs : SINGH V., ABDELAZIZ O., AUTE V., et al.
- Date : 12/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
Voir la fiche
-
HOW TO IMPROVE CONDENSER PERFORMANCE WITH ENHAN...
- Auteurs : HAGE M., KRIEGSMANN A.
- Date : 1989
- Langues : Anglais
- Source : Klima Kälte Heiz. - n. spec.
Voir la fiche
-
A flexible hybrid CFD model for refrigerant mal...
- Auteurs : YOU Y., WU Z., LIU H., et al.
- Date : 07/2018
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 91
- Formats : PDF
Voir la fiche
-
Enhancement of heat transfer from air-fin coole...
- Auteurs : WALCZYK H.
- Date : 1993
- Langues : Anglais
- Source : Chem. Eng. Process. - vol. 32 - n. 2