Résumé
Performances of a water-source CO2 heat pump coupled with hot and cold thermal storage were investigated experimentally in this study. This combined system was tested by controlling compressor frequency, expansion valve opening, and hot and cold circulated water flow rates. Experimental results shows that higher compressor frequency leads to a shorter energy charging time and a higher overall coefficient of performance (COP) of the combined system during the charging process. Expansion valve opening affects the COPs significantly but affects the thermal stratification in thermal storage tanks slightly. Low hot and cold water flow rates lead to the good thermal stratification in storage tanks, which is beneficial for the overall COP of the combined system during the charging process, although high water flow rates are beneficial for the transient COP of heat pump at the beginning of the charging process. The overall COP reaches maximum when the hot and cold water flow rates were set as 0.1 m3/h and 0.2 m3/h respectively at the compressor frequency of 50 Hz and at the expansion valve opening of 330 pulses. Based on the test data, the correlations of COP with the outlet water temperature of thermal storage tanks were developed for further optimizing this combined system.
Détails
- Titre original : Experimental performance study on a dual-mode CO2 heat pump system with thermal storage.
- Identifiant de la fiche : 30021170
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 115
- Date d'édition : 25/03/2017
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2016.12.095
Liens
Voir d'autres articles du même numéro (31)
Voir la source
Indexation
-
CALCUL DU VOLUME DE STOCKAGE DES CONSTITUANTS D...
- Auteurs : DIETRICH E., BOURGOGNE P., LE GOFF P.
- Date : 1985
- Langues : Français
- Source : Rev. gén. Therm. - vol. 24 - n. 288
Voir la fiche
-
Simulation and optimization analysis of a dual-...
- Auteurs : WANG Y., ZHAO H., WANG X., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
QUALIFICATION OF HIGH PERFORMANCE HEAT PUMP: EV...
- Auteurs : AKAI M.
- Date : 12/03/1990
- Langues : Anglais
Voir la fiche
-
CO2 dual source solar assisted heat ...
- Auteurs : ZANETTI E., AZZOLIN M., CONTE R., GIROTTO S., DEL COL D.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
LES POMPES A CHALEUR SUR CAPTEURS ATMOSPHERIQUE...
- Auteurs : MOLLE N.
- Date : 05/1987
- Langues : Français
Voir la fiche