Document IIF
Étude expérimentale sur la performance d’une pompe à chaleur au CO2 transcritique équipée d’un système d’expansion multi-éjecteur.
Experimental investigation on the performance of a transcritical CO2 heat pump with multi-ejector expansion system.
Auteurs : BOCCARDI G., BOTTICELLA F., LILLO G., et al.
Type d'article : Article, Article de la RIF
Résumé
Carbon dioxide is becoming an interesting option also for HVAC heating appliances due to its eco-friendly characteristics. The incurrence of transcritical cycles makes the use of ejectors attractive to improve performance. Part load conditions and varied ambient temperatures imply the use of variable geometry systems of appropriate design to keep their efficiency high. This paper investigates experimentally a multi-ejector air-to-water CO2 heat pump for heating needs, measuring the performance of the system and of each component under partial and full load conditions. A sensitivity analysis was run varying, separately or in a combined way, the following parameters or operating conditions: ejector area ratio in a range of 33.1–86.6%; compressor frequency in the range of 30–60?Hz; ambient temperature in the range of -15–12?°C according to the standard UNI EN 14511/2011. The results show the possibility to reach an optimum of the COP by varying the ejector area, once the other parameters are fixed, as a consequence of the ejector regulation on the pressures at the inlet and outlet of the compressor.
Documents disponibles
Format PDF
Pages : 389-400
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the performance of a transcritical CO2 heat pump with multi-ejector expansion system.
- Identifiant de la fiche : 30022318
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Date d'édition : 10/2017
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.06.013
Liens
Voir d'autres articles du même numéro (42)
Voir la source
-
Performance assessment of an off-the-shelf R744...
- Auteurs : MINETTO S., BRIGNOLI R., BANASIAK K., et al.
- Date : 09/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 59 - n. 1-2
Voir la fiche
-
Characteristics of a two-phase ejector in carbo...
- Auteurs : AKAGI S., WANG J. F., HIHARA E.
- Date : 02/05/2005
- Langues : Anglais
- Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
Voir la fiche
-
Characteristics of pressure recovery in a two-p...
- Auteurs : AKAGI S., DANG C., HIHARA E.
- Date : 20/05/2008
- Langues : Anglais
- Source : 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
Voir la fiche
-
Experimental investigation on transcritical CO2...
- Auteurs : WEI J., CHEN Q., TANG L., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Caractéristiques de la performance d'une pompe ...
- Auteurs : AKAGI S., DANG C. B., HIHARA E.
- Date : 2006
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 23 - n. 1
Voir la fiche