Etude expérimentale sur la pression de vapeur d'isobutane (R600a).

[In Chinese. / En chinois.]

Auteurs : WANG Z. W., DUAN Y. Y., SUN X. Y.

Type d'article : Article

Résumé

The vapour pressure of isobutane (R600a) was measured using a modified Burnett PvTx apparatus at temperatures from 253 to 393 K and pressures from 73 to 2833 kPa. The measurement uncertainties were estimated to be within for temperature and within for pressure. A new vapour pressure equation was developed to represent the experimental data of R600a. The present equation was also compared with available literature data. The normal boiling point and acentric factor of R600a were also determined.

Documents disponibles

Format PDF

Pages : 24-28

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : [In Chinese. / En chinois.]
  • Identifiant de la fiche : 2006-0534
  • Langues : Chinois
  • Source : Journal of Refrigeration - vol. 26 - n. 104
  • Date d'édition : 06/2005

Liens


Voir d'autres articles du même numéro (5)
Voir la source