Étude expérimentale sur le système de confinement des allées chaudes pour le refroidissement des armoires d’un centre de données.
Experimental investigation on ducted hot aisle containment system for racks cooling of data center.
Résumé
A new type of ducted hot aisle containment system for racks cooling of data center has been proposed and put into practice gradually. However, the related academic research has not been carried out, especially for the improvement of cooling performance and influencing factors for the cooling system. In this paper, one experiment platform with 8 racks in 2 rows with multiple-heat-sources was established and tested under various working scenarios. In terms of improving the cooling performance, airtight treatment on the basis of ducted hot aisle containment system is better than itself and is also better than only collar, which is better than no collar. Besdides, doors closing is better than that doors opening, "V" diffuser is better than "T" diffuser, and “T” diffuser is better than no diffuser. Properly increasing installation ratio of blanking panels and air volume have also favorable impact. The experimental data and results in this paper will be of great significance to the design and application of ducted hot aisle containment system for racks cooling.
Documents disponibles
Format PDF
Pages : 11
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on ducted hot aisle containment system for racks cooling of data center.
- Identifiant de la fiche : 30028328
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 127
- Date d'édition : 07/2021
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2021.02.006
Liens
Voir d'autres articles du même numéro (25)
Voir la source
Indexation
-
Analysis on the large temperature difference di...
- Auteurs : ZHANG T., LIU X., JIANG J., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Conception et analyse d'un système de condition...
- Auteurs : LIU Q., WANG J., JING Y.
- Date : 10/2013
- Langues : Chinois
- Source : HV & AC - vol. 43 - n. 282
- Formats : PDF
Voir la fiche
-
REDUCING HIGH COSTS. USED.
- Date : 05/1982
- Langues : Anglais
- Source : Heat. Aircond. Refrig. - vol. 14 - n. 5
Voir la fiche
-
Expérience à échelle réelle pour un système de ...
- Auteurs : TSUCHIYA T., SUWA Y., OOKA R.
- Date : 11/2013
- Langues : Japonais
- Source : Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 200
Voir la fiche
-
Klimatechnik mit Wasser und Kältemittel.
- Auteurs : KRONSTRÖM U.
- Date : 22/11/2007
- Langues : Allemand
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche