Document IIF
Etude expérimentale sur les effets de la température superficielle et de la rétention d'eau sur le givrage d'un échangeur de chaleur compact à microcanaux pour les systèmes à pompe à chaleur.
Experimental investigation of the surface temperature and water retention effects on the frosting performance of a compact microchannel heat exchanger for heat pump systems.
Auteurs : MOALLEM E., PADHMANABHAN S., CREMASCHI L., et al.
Type d'article : Article, Article de la RIF
Résumé
Frost formation on a louvered fin microchannel heat exchanger was experimentally investigated in this paper with the aim of determining the dominant factors affecting the time of frosting and frost growth rate. A novel methodology was developed to measure frost thickness and frost weight at intervals during the frosting period. Frost mass and thickness growth rates, corresponding coil heat transfer, capacity degradations and air pressure drop are measured and discussed. The experimental data showed that at a given air dry bulb temperature, the fin surface temperature and air humidity are the primary parameters that influence the frost growth rates. Water retention and air velocity had a secondary impact on the frosting performance. From digital images of the frost growth it was observed that frost does not nucleate from the water droplets retained in between fins but it developed from the leading edges of the fins.
Documents disponibles
Format PDF
Pages : 171-186
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation of the surface temperature and water retention effects on the frosting performance of a compact microchannel heat exchanger for heat pump systems.
- Identifiant de la fiche : 30003247
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 1
- Date d'édition : 01/2012
Liens
Voir d'autres articles du même numéro (18)
Voir la source
-
Effects of surface coating and water retention ...
- Auteurs : MOALLEM E., HONG T., CREMASCHI L., et al.
- Date : 05/2013
- Langues : Anglais
- Source : HVAC&R Research - vol. 19 - n. 4
Voir la fiche
-
A new dynamic heat exchanger model with frostin...
- Auteurs : QIAO H., AUTE V., RADERMACHER R.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Comparison of energy supplies and consumptions ...
- Auteurs : XIONG T., YING Y., HAN B., YAN G., YU J.
- Date : 12/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 132
- Formats : PDF
Voir la fiche
-
Frosting characteristics of fin-tube heat excha...
- Auteurs : HAN X., FAN W., QU M., et al.
- Date : 06/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 67 - n. 1-2
Voir la fiche
-
The effects of the orientation of outdoor micro...
- Auteurs : ZHANG W., HRNJAK P.
- Date : 10/07/2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche