Recommandé par l'IIF / Document IIF
Étude expérimentale sur les performances de refroidissement d’un congélateur à ultra-basse température (-80 °C).
Experimental investigation on the pull-down performance of a -80°C ultra-low temperature freezer.
Résumé
This paper presents an experimental investigation on the pull-down performance of a -80°C ultra-low temperature freezer. Experiments were conducted in a two-stage cascade refrigeration system with an inner recuperative heat exchanger in low temperature cycle (LTC). In addition, the pull-down performances of the freezer were discussed on different startup temperatures ranging from -20°C to 24°C when the ambient temperature was fixed at 26°C. In this paper, the cooling process was divided into early start-up phase, rapid cooling phase and stable cooling phase, and it was found that thermal parameters changed obviously with the startup temperatures, especially in the rapid cooling phase. The experimental results showed that there were maximum discharge temperatures of LTC compressor during pull-down process, and the maximum values increased with the rise of startup temperatures. When the startup temperature was -20°C, the maximum discharge temperature of LTC compressor was 8.1% (11.6°C) lower than that when the startup temperature was 24°C. As two factors affecting the discharge temperature of LTC significantly, the superheating degree was the main influencing factor in rapid cooling phase, while the decrease of the evaporation and condensation pressures had a more significant effect in the stable cooling phase. Besides, the volumetric efficiency of high temperature cycle (HTC) compressor deteriorated more obviously during the pull-down process, and had higher potential for performance improvement compared with that of LTC.
Documents disponibles
Format PDF
Pages : 1-10
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental investigation on the pull-down performance of a -80°C ultra-low temperature freezer.
- Identifiant de la fiche : 30027776
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 119
- Date d'édition : 11/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.04.030
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (41)
Voir la source
Indexation
-
Modeling of an ultra-low temperature refrigerat...
- Auteurs : BANI ISSA A. M. Abd, PERGANTIS E.N., BREHM J. K., GROLL E. A., ZIVIANI D.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
A system designed for a pharmaceutical producti...
- Auteurs : ROLFSMAN L.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Performance optimisation of an ultra-low temper...
- Auteurs : EXPÓSITO CARRILLO J. A., SÁNCHEZ DE LA FLOR F. J., SALMERÓN LISSEN J. M., RODRIGUEZ JARA E. A. , RUIZ PARDO A.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
EU F-Gas Regulation guidance. Information sheet...
- Auteurs : Gluckman Consulting, Defra (Department for Environment, Food and Rural Affairs), Jacobs
- Date : 01/2015
- Langues : Anglais
- Source : gluckmanconsulting.com
Voir la fiche
-
Performance analysis of a cascade room temperat...
- Auteurs : ZHANG Y., WU J., ZHANG H.
- Date : 11/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 143
- Formats : PDF
Voir la fiche