ETUDE EXPERIMENTALE SUR LES PROPRIETES MASSE/VOLUME/TEMPERATURE DU FRIGORIGENE DE REMPLACEMENT 1,1,1,2-TETRAFLUOROETHANE (R134A).

AN EXPERIMENTAL STUDY FOR PVT PROPERTIES OF CFC ALTERNATIVE REFRIGERANT 1,1,1,2-TETRAFLUOROETHANE (R134A).

Résumé

DANS L'ARTICLE, ON RAPPORTE LES DONNEES EXPERIMENTALES CONCERNANT LES PROPRIETES MASSE/VOLUME/TEMPERATURE DU R134A. ON A MESURE 159 DONNEES SUR CES PROPRIETES, LE LONG DE 24 ISOCHORES, DANS UNE PLAGE DE TEMPERATURES COMPRISES ENTRE 310 ET 425 K, DE PRESSIONS COMPRISES ENTRE 0,7 ET 12 MEGAPASCALS ET DE MASSES VOLUMIQUES COMPRISES ENTRE 36 ET 1.144 KG/M3. ON A MESURE 51 PRESSIONS DE VAPEUR A DES TEMPERATURES ALLANTDE 300 K A LA TEMPERATURE CRITIQUE. ON A MIS AU POINT UNE EQUATION DE LA PRESSION DE VAPEUR REPRESENTANT LES DONNEES EXPERIMENTALES DANS DES LIMITES DE 0,2 %. LA PRESSION CRITIQUE A ETE EVALUEE A 4,0640 PLUS OU MOINS 0,0015 MEGAPASCAL LORS DU DEVELOPPEMENT DE L'EQUATION DE LA PRESSION DE VAPEUR, A L'AIDE DE LA TEMPERATURE CRITIQUE ET DE LA DENSITE MESUREES PAR LES AUTEURS EN 1988.

Détails

  • Titre original : AN EXPERIMENTAL STUDY FOR PVT PROPERTIES OF CFC ALTERNATIVE REFRIGERANT 1,1,1,2-TETRAFLUOROETHANE (R134A).
  • Identifiant de la fiche : 1991-0575
  • Langues : Anglais
  • Date d'édition : 1990
  • Source : Source : ASHRAE Trans.
    vol. 96; n. 1; 132-140; 6 fig.; 4 tabl.; 7 ref.
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.