Résumé
An experiment on the performance of a cascade refrigeration system with NH3/CO2 was conducted and its performance was compared with that of a two-stage NH3 cycle or a single-stage NH3 cycle. The results show that the COP of the cascade system increases at first and then decreases with the increase in the CO2 condensing temperature. Moreover, the system COP increases with a decrease of the temperature difference in the evaporator-condenser or with an increase in CO2 evaporating temperature. In addition, the COP of the NH3/CO2 cascade cycle is greater than that of the two-stage NH3 cycle or the single-stage NH3 cycle at the lower evaporating temperatures.
Documents disponibles
Format PDF
Pages : pp. 21-24
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2010-0747
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 30 - n. 3
- Date d'édition : 06/2009
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2009.03.021
Liens
Voir d'autres articles du même numéro (4)
Voir la source
Indexation
-
Thèmes :
Ammoniac;
CO2 - Mots-clés : Système frigorifique; Ammoniac; Système à compression; Système en cascade; Experimentation; COP; Frigorigène; Compresseur à vis; CO2
-
Experimental investigation on the performance o...
- Auteurs : WANG B., WU H., LI J., et al.
- Date : 09/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 6
- Formats : PDF
Voir la fiche
-
Screw compressor packages: considerations for u...
- Auteurs : KLIDONAS G. P.
- Date : 05/2005
- Langues : Anglais
- Source : Afr. Heat. Cool. - vol. 6 - n. 1
Voir la fiche
-
Cascade performance analysis.
- Auteurs : PEARSON A.
- Date : 02/03/2001
- Langues : Anglais
- Source : C-dig, the Carbon dioxide interest group. Presentations from meetings [CD-ROM].
Voir la fiche
-
CO2-ammonia cascade test plant with screw compr...
- Auteurs : MOSEMANN D.
- Date : 02/03/2001
- Langues : Anglais
- Source : C-dig, the Carbon dioxide interest group. Presentations from meetings [CD-ROM].
Voir la fiche
-
Cooling systems working with natural refrigerants.
- Auteurs : AKABOSHI S., MACHIDA A., IKEDA Y., et al.
- Date : 05/12/2002
- Langues : Anglais
- Source : The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2002: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
Voir la fiche