Etude expérimentale sur un type différent de système frigorifique en cascade à compression de vapeur.
An experimental investigation of a different type of vapour-compression cascade refrigeration system.
Auteurs : KILICARSLAN A.
Type d'article : Article
Résumé
This article describes an experimental investigation and theoretical study on a different type of two-stage vapour compression cascade refrigeration system using R134 as the refrigerant. Performance evaluations of two single stage vapour-compression systems and a two-stage vapour-compression refrigeration cascade system are performed with respect to theoretical model developed. In the first section of the experiments, one refrigeration system, namely RU2, is operated. During the experiments, the rate of the water flow connecting both systems is kept constant at various values and the voltage across evaporator heaters is increased from 100 to 200 V with intervals of 20 V. In the second part of the first category, experiments are repeated by using different mass flow rates of water. In the second section, two separate refrigeration systems, namely RU1 and RU2 are connected to each other by using the water loop. This system is also called cascade refrigeration system. It is observed that the change in water mass flow rate has little effect on the coefficient of performance for single stage and cascade stage refrigeration systems. It is also observed that the coefficient of performance is mainly a function of evaporator temperature and pressure. When RU2 operating in the single stage refrigeration system is compared with RU2 operating in the two-stage cascade refrigeration system at the same refrigeration load interval (360-460 W), the average percentage values of the decrease in the condensing pressure, the decrease in the compressor power and the increase in the COP are 21.9, 31.7 and 32.7, respectively.
Détails
- Titre original : An experimental investigation of a different type of vapour-compression cascade refrigeration system.
- Identifiant de la fiche : 2005-0669
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 24 - n. 17-18
- Date d'édition : 12/2004
Liens
Voir d'autres articles du même numéro (13)
Voir la source
Indexation
-
Thèmes :
Systèmes à compression;
HFC - Mots-clés : R134a; Comparaison; Recherche; Système biétage; Système à compression; Performance; Système en cascade; COP
-
Thermodynamic analysis of a R744-R717 cascade r...
- Auteurs : MESSINEO A., PANNO G.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
The natural fluid nitrous oxide: an option as s...
- Auteurs : KRUSE H., RÜSSMANN H.
- Date : 08/2006
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 5
- Formats : PDF
Voir la fiche
-
Experimental performance of a cascade refrigera...
- Auteurs : RAHADIYAN L., KIM Y. G., SHIN Y. S., et al.
- Date : 16/02/2006
- Langues : Anglais
- Source : Innovative Equipment and Systems for Comfort and Food Preservation.
- Formats : PDF
Voir la fiche
-
Development of high performance heat pump syste...
- Auteurs : HASEGAWA H., SAIKAWA M., HASHIMOTO K., IWATSUBO T.
- Date : 22/09/1996
- Langues : Anglais
- Source : Heat pumping technologies towards the next century: applications and markets. Proceedings of the 5th IEA Conference.
Voir la fiche
-
Experimental comparison of a cascade refrigerat...
- Auteurs : QUEIROZ M. V. A., PANATO V. H., ANTUNES A. H. P., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche