Étude expérimentale sur une pompe à chaleur eau-eau monovalente à variateur de vitesse munie d'un désurchauffeur pour les maisons à basse consommation d'énergie.
Experimental study on a monovalent inverter-driven water-to-water heat pump with a desuperheater for low energy houses.
Auteurs : BLANCO D. L., NAGANO K., MORIMOTO M.
Type d'article : Article
Résumé
In this study, a novel monovalent inverter-driven water-to-water heat pump with a desuperheater was developed. In this unique system, domestic hot water is produced at a constant temperature controlled by a variable flow rate and stored in a tank. The heat demand is constantly matched by the system through the use of an inverter-driven compressor, which eliminates the need for a buffer tank. Three heating configurations of the system were examined with respect to variable climate conditions and two space heating target temperatures: space heating (mode 1), domestic hot water production (mode 2) and a combination of both (mode 3). Mappings of the performance variables per frequency were constructed for mode 3. For the other modes, the highest COP was identified for each examined climate condition. The difference between modes 1 and 3 was less than 5% for every variable. The space heating target temperature had a strong influence on both modes, showing an average difference of 29% in the COP between 35 °C and 45 °C. Mode 2 exhibited a considerably reduced COP compared to the other modes, as well as the lowest refrigerant mass flow rate and highest compression ratio among the three modes. From the previous results and the examination of the compressor, the compression ratio presents itself as a key parameter that can help to increase the COP if maintained at low values. The results of this research could be applied to the design of a control methodology for monovalent heat pumps.
Détails
- Titre original : Experimental study on a monovalent inverter-driven water-to-water heat pump with a desuperheater for low energy houses.
- Identifiant de la fiche : 30006098
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 50 - n. 1
- Date d'édition : 01/2013
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2012.07.008
Liens
Voir d'autres articles du même numéro (64)
Voir la source
-
Evolution de la performance des PAC air-eau rév...
- Auteurs : LÓPEZ R.
- Date : 09/2012
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 102 - n. 1126
Voir la fiche
-
Integrated control system with DC inverter tech...
- Auteurs : MUVEGI W., LAMANNA B.
- Date : 05/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Comparison of the heating performance of an inv...
- Auteurs : ROH C. W., KIM M. S.
- Date : 03/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 2
- Formats : PDF
Voir la fiche
-
Experimental analysis of a variable capacity he...
- Auteurs : MADANI H., AHMADI N., CLAESSON J., et al.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Global unsteady state simulation of compression...
- Auteurs : OHNO K., SAITO K.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche