Document IIF
Comparaison de la performance en mode chauffage d'un système de pompe à chaleur à vitesse variable utilisant l'injection de vapeur de R410A dans l'accumulateur et le compresseur.
Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor.
Résumé
In cold regions, a refrigerant injection technique has been used for enhancing heating capacity and avoiding the excessively high discharge temperature which is detrimental to reliability of a heat pump system. The heat pump system in this study having an additional refrigerant injection line into the accumulator was tested to compare with the heating performances of classic vapor-injection cycle. The heat pump system was designed to inject vapor refrigerant into the compressor and accumulator, selectively. Although the refrigerant injection into the compressor (classic vapor-injection cycle) was more effective to enhance heating capacity, the refrigerant injection into the accumulator could decrease discharge temperature and increase both heating capacity and COP slightly at the condition of high compressor frequency. In terms of mass balance, the injection stream into the accumulator substituted the evaporator's suction stream flowing to the compressor, so the mass flow rate of condenser was not increased as much as the amount of injected refrigerant.
Documents disponibles
Format PDF
Pages : 434-444
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor.
- Identifiant de la fiche : 30003300
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 2
- Date d'édition : 03/2012
Liens
Voir d'autres articles du même numéro (22)
Voir la source
-
High efficiency inverter scroll compressors.
- Auteurs : MURAKAMI Y., KITAURA H., MATSUKAWA K., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 23rd International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental analysis of a variable capacity he...
- Auteurs : MADANI H., AHMADI N., CLAESSON J., et al.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
CFD analysis and experiment study of the rotary...
- Auteurs : DENG L., LIANG S., XU J., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 23rd International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Equipos de refrigeración con tecnología inverte...
- Auteurs : ROCHINA BELTRÁN R.
- Date : 07/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 438
- Formats : PDF
Voir la fiche
-
Integrated control system with DC inverter tech...
- Auteurs : MUVEGI W., LAMANNA B.
- Date : 05/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF