Document IIF
Comparaison de la performance en mode chauffage d'un système de pompe à chaleur à vitesse variable utilisant l'injection de vapeur de R410A dans l'accumulateur et le compresseur.
Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor.
Résumé
In cold regions, a refrigerant injection technique has been used for enhancing heating capacity and avoiding the excessively high discharge temperature which is detrimental to reliability of a heat pump system. The heat pump system in this study having an additional refrigerant injection line into the accumulator was tested to compare with the heating performances of classic vapor-injection cycle. The heat pump system was designed to inject vapor refrigerant into the compressor and accumulator, selectively. Although the refrigerant injection into the compressor (classic vapor-injection cycle) was more effective to enhance heating capacity, the refrigerant injection into the accumulator could decrease discharge temperature and increase both heating capacity and COP slightly at the condition of high compressor frequency. In terms of mass balance, the injection stream into the accumulator substituted the evaporator's suction stream flowing to the compressor, so the mass flow rate of condenser was not increased as much as the amount of injected refrigerant.
Documents disponibles
Format PDF
Pages : 434-444
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of the heating performance of an inverter-driven heat pump system using R410A vapor-injection into accumulator and compressor.
- Identifiant de la fiche : 30003300
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 2
- Date d'édition : 03/2012
Liens
Voir d'autres articles du même numéro (22)
Voir la source
-
Evolution de la performance des PAC air-eau rév...
- Auteurs : LÓPEZ R.
- Date : 09/2012
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 102 - n. 1126
Voir la fiche
-
Experimental study on a monovalent inverter-dri...
- Auteurs : BLANCO D. L., NAGANO K., MORIMOTO M.
- Date : 01/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 50 - n. 1
Voir la fiche
-
Experimental study on an inverter heat pump wit...
- Auteurs : WANG F., WANG F. K., FAN X., et al.
- Date : 06/2012
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 39
Voir la fiche
-
Méthodes de régulation du variateur de vitesse ...
- Auteurs : MAURO B., KAMZOLOV S.
- Date : 03/2013
- Langues : Russe
- Source : Holodil'nyj Biznes - n. 3
- Formats : PDF
Voir la fiche
-
Enhancement of heat pump performance by pulsati...
- Auteurs : ROH C. W., KIM M. S.
- Date : 09/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 6
- Formats : PDF
Voir la fiche