Résumé
The work investigates the performance of a CO2 heat-pump/chiller unit integrated with a thermal storage system to mainly provide for the domestic hot water demands of a hotel building. The thermal storage system consists of a tank holds at fully charged conditions 5m3 of hot water leaving the gas cooler at 70°C and 145 kWh of energy capacity. The heat pump’s evaporator is connected to the hotel chilled water system (12 °C to 6.5 °C) and provides a cooling capacity of 37 kW. A dynamic numerical model for the system was developed and simulation results have shown that a heat pump with a nominal heating capacity of 50 kW and a daily operation of almost 14 hours would have a COP of 6.7 and a complete system ‘s COP of 5.7 if the circulating pumps are considered. This presents an energy efficient solution if compared to a convenient boiler heating system and a separate chiller with a COP up to 3.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2 heat pump/chiller system for a hotel in a tropical climate: a numerical investigation.
- Identifiant de la fiche : 30029818
- Langues : Anglais
- Sujet : Technologie
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Date d'édition : 13/06/2022
- DOI : http://dx.doi.org/10.18462/iir.gl2022.0261
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (169)
Voir le compte rendu de la conférence
Indexation
-
Numerical performance investigation of a CO2 he...
- Auteurs : SMITT S. M., HAFNER A.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Numerical simulation of an integrated CO2<...
- Auteurs : HENKE L., ELARGA H., HAFNER A.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Integrated R744 unit for hotels: Analysis of fi...
- Auteurs : SMITT S. M., TOLSTOREBROV I., HAFNER A.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
Integrated R744 heat pump/chiller for hotel: st...
- Auteurs : SINGH S., HAFNER A., ELARGA H., SHARMA K.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Advantage of CO2 heat pump chiller f...
- Auteurs : REDDY Y. S. K., ELARGA H., GURUCHETHAN A. M., MAIYA M. P., HAFNER A.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche