Étude sur l’efficacité de l’utilisation de panneaux d’isolation sous vide dans les réfrigérateurs domestiques.

A study on the effectiveness of applying vacuum insulation panels in domestic refrigerators.

Auteurs : THIESSEN S., KNABBEN F. T., MELO C., et al.

Type d'article : Article, Article de la RIF

Résumé

In this work the thermodynamic behavior of a typical domestic refrigerator insulated in 16 distinct ways with vacuum insulation panels (VIPs) was experimentally evaluated. As expected, it was found that the energy consumption is affected by both the coverage area and the position of the panels. It was also found that samples with the same coverage area presented distinct energy consumptions and vice-versa. The gathered data were correlated statistically in order to identify the most promising regions to install the panels. It was observed that the energy consumption is reduced by approximately 6% and 11% when the doors and the rear wall are insulated with VIPs, respectively. It was also found that a coverage area of 56% drops the energy consumption by 21%.

Documents disponibles

Format PDF

Pages : 10-16

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A study on the effectiveness of applying vacuum insulation panels in domestic refrigerators.
  • Identifiant de la fiche : 30025219
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
  • Date d'édition : 12/2018
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.09.006