Etude sur l'influence des conditions ambiantes psychrométriques sur les retombées d'eau vésiculaire des tours de refroidissement.
On the influence of psychrometric ambient conditions on cooling tower drift deposition.
Auteurs : LUCAS M., MARTÍNEZ P. J., RUIZ J., et al.
Type d'article : Article
Résumé
Water drift emitted from cooling towers is objectionable for several reasons, mainly due to human health hazards. A numerical model to study the influence of psychrometric ambient conditions on cooling tower drift deposition was developed as a tool to evaluate liquid droplet dispersion and risk area. Both experimental plume performance and drift deposition were employed to validate the numerical results. This study shows the influence of variables like ambient dry bulb temperature, ambient absolute humidity and droplet exit temperature from cooling tower on the drift evaporation (and therefore deposition) and on the zone affected by the cooling tower. The strongest effect detected corresponds to the ambient dry bulb temperature. When a higher ambient temperature was present, deposition was lower (evaporation was therefore higher) and the zone affected by the cooling tower was smaller. The influence of the other two variables included in the study was weaker than the dry bulb ambient temperature. A high level of ambient absolute humidity increased drift deposition and also the size of the zone affected by the cooling tower. Finally, a high level of droplet exit temperature decreased deposition and increased the zone affected by the cooling tower. [Reprinted with permission from Elsevier. Copyright, 2009].
Détails
- Titre original : On the influence of psychrometric ambient conditions on cooling tower drift deposition.
- Identifiant de la fiche : 2010-1445
- Langues : Anglais
- Sujet : Environnement
- Source : International Journal of Heat and Mass Transfer - vol. 53 - n. 4
- Date d'édition : 31/01/2010
- DOI : http://dx.doi.org/10.1016/j.ijheatmasstransfer.2009.10.037
Liens
Voir la source
Indexation
- Thèmes : Evaporateurs, condenseurs et autres échangeurs thermiques
- Mots-clés : Aspersion; CFD; Tour de refroidissement; Simulation; Environnement; Eau
-
COOLING TOWER FIRE PROTECTION: A SOUND BUSINESS...
- Auteurs : VIEIRA S. F.
- Date : 04/1988
- Langues : Anglais
- Source : Heat. Pip. Air Cond. - vol. 60 - n. 4
Voir la fiche
-
Numerical analysis of solar enhanced natural dr...
- Auteurs : ZHOU Z., GONG H.
- Date : 05/02/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 94
Voir la fiche
-
Modélisation d’un écoulement diphasique évapora...
- Auteurs : RAOULT F.
- Date : 31/01/2019
- Langues : Français
- Formats : PDF
Voir la fiche
-
Characterization and performance of spray nozzl...
- Auteurs : TOGNOTTI L., ZANELLI S., BELLAGAMBA B., et al.
- Date : 07/1991
- Langues : Anglais
- Source : NIST spec. Publ. - NIST SP 813; ICLASS-91; 787-795; 8 fig.; 3 tabl.; 9 ref.
Voir la fiche
-
Numerical simulation of water spray in natural ...
- Auteurs : ALKHEDHAIR A., JAHN I., GURGENCI H., et al.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche