Résumé
Adsorption performance is tested for the composite adsorbent by the volumetric measurement method. There are no expansion spaces for the composite adsorbent because there only have a dead volume 4.7 cm3 in the adsorber to transfer the adsorbate. The mass ratio of the CaCl2 and the expanded graphite is 4:1. The experimental results show that the equilibrium adsorption isosteres occur when the temperature rising speed of the adsorber is lower than or equal to 0.4°C/minute from 15 to 100°C.The relation between the equilibrium adsorption quantity, temperature and pressure of the adsorber is studied in this paper, the results show that, the equilibrium curves of the heating process and the cooling process match well together at constant adsorption quantity. The experiment results also show that the optimal working range of the adsorption quantity of the composite adsorbent is from 0.55 to 1.0 (g/g) and the maximum cycle cooling capacity of the working pairs calculated by the tested results is 585kJ/kg for an adsorption refrigerator at the general working conditions, condensing temperature 30°C, evaporating temperature -25°C, the desorption temperature 100°C and cooling water temperature 15°C.
Documents disponibles
Format PDF
Pages : ICR07-B1-1500
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Study on the adsorption performance of composite adsorbent of CaCl2 and expanded graphite with ammonia as adsorbate.
- Identifiant de la fiche : 2007-2593
- Langues : Anglais
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/08/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Systèmes à absorption et adsorption
- Mots-clés : Ammoniac; Système à adsorption; Optimisation; Graphite; Experimentation; Cycle; Chlorure de calcium
-
Experimental study of a novel CaCl2/expanded gr...
- Auteurs : LI S. L., XIA Z. Z., WU J. W., et al.
- Date : 01/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 1
- Formats : PDF
Voir la fiche
-
Evaluation of the cooling performance of a cons...
- Auteurs : OLIVEIRA R. G., WANG R. Z., WANG C.
- Date : 01/2007
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 1
- Formats : PDF
Voir la fiche
-
Dynamic characteristics of a chemical heat pump...
- Auteurs : FUJIOKA K., SUZUKI H., MIYATANI N., et al.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
A combined double-way chemisorption refrigerati...
- Auteurs : LI T. X., WANG R. Z., OLIVEIRA R. G., et al.
- Date : 01/2009
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 1
- Formats : PDF
Voir la fiche
-
Development of a new synthesized adsorbent for ...
- Auteurs : DAOU K., WANG R. Z., XIA Z. Z.
- Date : 01/2006
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 26 - n. 1
Voir la fiche