Document IIF
Études des performances d’un réfrigérateur magnétique à température ambiante à deux régénérateurs avec une plage de température de 26 °C.
Performance study of a double-regenerator room temperature magnetic refrigerator with 26°C temperature span.
Résumé
Magnetic refrigeration (MR) has the characteristics of green environmental protection, high energy efficiency and reliable operation, which is expected to replace gas compression refrigeration in the future. Based on the principle of MR, Baotou Research Institute of Rare Earths (BRIRE) successfully developed a practical room temperature magnetic refrigerator with two regenerators. The performance of the magnetic refrigerator in different environments was studied, and the velocity distribution of the fluid in regenerator together with the temperature span between the cold end and hot end were analyzed by numerical calculation. The magnetic refrigerator is mainly composed of a refrigeration chamber, two regenerators, magnetic field system, valves, a pump and so on. The magnetic field system consists of two sets of double-layer annularly nested NdFeB permanent magnetic arrays, which can accommodate two regenerators. The magnetization and demagnetization of magnetic refrigerant are realized by the rotation of the inner magnetic array, and the range of generated magnetic field is 0-1.4 T. The magnetic refrigerator adopts 2 kg spherical Gd particles as magnetic refrigerant and water as heat exchange fluid, and the cycle frequency is 0.25 Hz. When the cold end is equipped with a 117 L refrigeration chamber at ambient temperature of 22 °C, the temperature of refrigeration chamber can reach 8 °C, and the refrigeration temperature span is 26 °C, which meets the requirement of the market for refrigeration. The maximum cooling power of the magnetic refrigerator measured by compensation method is 100 W. The simulation results of the temperature of flow and cold end are in good agreement with the experimental results.
Documents disponibles
Format PDF
Pages : 143-151
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance study of a double-regenerator room temperature magnetic refrigerator with 26°C temperature span.
- Identifiant de la fiche : 30031152
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 148
- Date d'édition : 04/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2023.01.007
Liens
Voir d'autres articles du même numéro (15)
Voir la source
-
Numerical modelling of graded active magnetic r...
- Auteurs : NIELSEN K. K., BAHL C. R. H., ENGELBRECHT K., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche
-
Modelling of a magnetocaloric system for coolin...
- Auteurs : GOVINDARAJU V. R., VILATHGAMUWA D. M., RAMANUJAN R. V.
- Date : 07/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 43
- Formats : PDF
Voir la fiche
-
Etude analytique sur le froid magnétique régéné...
- Auteurs : HIRANO S., KAWANAMI T., IKEGAWA M., et al.
- Date : 2010
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 27 - n. 1
Voir la fiche
-
Development of an experimental rotary magnetic ...
- Auteurs : HUANG B., LAI J. W., ZENG D. C., et al.
- Date : 08/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
Voir la fiche
-
The energy performances of a rotary permanent m...
- Auteurs : APREA C., GRECO A., MAIORINO A., et al.
- Date : 01/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 61
- Formats : PDF
Voir la fiche