Évaluation de l’impact de l’utilisation des substituts au R-404A à très faible GWP.

Assessing the impact of using very low GWP alternatives to R-404A.

Numéro : pap. 2150

Auteurs : SPLETZER S., MEDINA J., HUGHES J.

Résumé

Global pressures on hydrofluorocarbon (HFC) refrigerants have reached new levels. With ongoing country ratifications of the Kigali Amendment to the Montreal Protocol and refrigerant shortages across Europe driven by the F-Gas regulations, equipment manufacturers are working hard to implement lower global warming potential (GWP) solutions. R-404A is one of the higher GWP refrigerants (GWP100 Year = 3,922, per AR4) used widely in commercial refrigeration. Several very low GWP (LGWP) candidates have emerged as potential replacements. For many hermetic and split system applications, hydrofluoroolefin-based (HFO) blends represent lower flammability alternatives to hydrocarbon (HC) refrigerants, that also allow for significantly larger charge sizes. Two mildly flammable, very LGWP blends, XL40 (R-454A) and XL20 (R-454C) were tested and compared to the R-404A baseline performance of a commercially available, double-door, upright reach-in freezer via softoptimization testing. Refrigerant compatibility with lubricants and other system materials was also examined. Miscibility, water solubility, and dielectric properties were also characterized.

Documents disponibles

Format PDF

Pages : 10

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Assessing the impact of using very low GWP alternatives to R-404A.
  • Identifiant de la fiche : 30024418
  • Langues : Anglais
  • Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 09/07/2018

Liens


Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence