Résumé
This study introduces a newly developed open source framework to evaluate the Life Cycle Climate Performance (LCCP) of commercial refrigeration systems. This LCCP framework is used to compare the environmental impact of three typical commercial refrigeration system configurations: central direct expansion (DX), distributed DX, and combined secondary circuit (medium temperature) with central DX (low temperature). The environmental impact of the first two systems is compared using three refrigerants: R404A, R407F, and N-40. The third system is evaluated using L-40 in the high stage of the secondary circuit MT system while the standard DX (LT) employs the three refrigerants listed above. The evaluations are performed for six US cities and the hourly energy consumption of the systems, required for calculation of indirect emissions, is determined using EnergyPlus. The results include a sensitivity analysis to identify the relative importance of refrigerant charge and electricity production emissions when using lower GWP refrigerants.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : An evaluation of the environmental impact of commercial refrigeration systems using alternative refrigerants.
- Identifiant de la fiche : 30011792
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Date d'édition : 23/06/2014
Liens
- Voir les traductions : Evaluación del impacto ambiental de los sistemas de refrigeración comerciales utilizando refrigerantes alternativos.
Voir d'autres communications du même compte rendu (87)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Supermarchés, meubles de vente - Mots-clés : Système frigorifique; Application commerciale; Substitut; Modèle; LCCP; HFC; GWP
-
Evaluación del impacto ambiental de los sistema...
- Auteurs : BESHR M., AUTE V., FRICKE B., et al.
- Date : 04/2015
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 43 - n. 479
- Formats : PDF
Voir la fiche
-
Development of low global warming potential ref...
- Auteurs : ABDELAZIZ O., FRICKE B., VINEYARD E.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Ensayos de nuevas alternativas de bajo GWP al R...
- Auteurs : MINOR B., GERSTEL J.
- Date : 09/2014
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 42 - n. 472
- Formats : PDF
Voir la fiche
-
Nuovi refrigeranti a basso GWP alternativi al R...
- Auteurs : MINOR B., GERSTEL J.
- Date : 2013
- Langues : Italien
- Source : Industria & Formazione - vol. 37 - n. 374
- Formats : PDF
Voir la fiche
-
Ensayos de nuevas alternativas de bajo GWP al R...
- Auteurs : MINOR B., GERSTEL J.
- Date : 09/2013
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - n. 461
- Formats : PDF
Voir la fiche