Document IIF
Évaluation de la performance énergétique saisonnière d'une unité de pompe à chaleur géothermique avec des frigorigènes à faible PRP.
Seasonal energy performance evaluation of a geothermal heat pump unit with lower-GWP refrigerants.
Numéro : 0735
Auteurs : SANTOS J. M., SIERES J., ORTEGA I., CERDEIRA F., ALVAREZ E.
Résumé
Nowadays, due to the energy and environmental crisis, using renewable energy is considered to reduce environmental pollution. In this context, heat pumps have been identified as a promising option for replacing fossil fuel-based equipment used in the building sector for heating applications. However, to lower the environmental impact of greenhouse gas (GHG) emissions, alternative lower-global warming potential (GWP) refrigerants must also replace the extensive use of high GWP refrigerants currently found in the market, such as R410A.
Lower-GWP (GWP<750) refrigerants have recently become a topic of widespread research interest for the continuing development of vapor compression heat pumps, that have become more and more widely used.
In this paper, we analyse the performance of lower-GWP alternative refrigerants for R-410A and draw conclusions on their relative performances in terms of heating capacity, seasonal coefficient of performance (SCOP), discharge temperature… The results have practical value in engineering heat pumps in an economy that is compelled to change by the consequences and uncertainties of climate change.
Documents disponibles
Format PDF
Pages : 11
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Seasonal energy performance evaluation of a geothermal heat pump unit with lower-GWP refrigerants.
- Identifiant de la fiche : 30031459
- Langues : Anglais
- Sujet : Technologie, Alternatives aux HFC
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Date d'édition : 21/08/2023
- DOI : http://dx.doi.org/10.18462/iir.icr.2023.0735
Liens
Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence
Indexation
-
SCOP experimental comparison of refrigerants R4...
- Auteurs : ORTEGA I., SIERES J., CERDEIRA F., SANTOS J. M., ALVAREZ E.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Residential Split Heat Pump Using Low GWP Refri...
- Auteurs : SHEN B., ALLY M.
- Date : 31/08/2021
- Langues : Anglais
- Source : 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
Voir la fiche
-
Low GWP HFO Refrigerants for extended temperatu...
- Auteurs : CHRISTMANN J. M., CODELLA F., KÜPPER H. D., SAAB S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Numerical modelling and seasonal performance an...
- Auteurs : DONGELLINI M., NALDI C., SIANI R., MORINI G. L.
- Date : 01/09/2021
- Langues : Anglais
- Source : 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Experimental study of R454B drop-in performance...
- Auteurs : ORTEGA I., SIERES J., CERDEIRA F., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche