Evaluation de la performance sous des conditions de fonctionnement réelles d'un système à plusieurs pompes à chaleur géothermiques.
Performance evaluation under the actual operation condition of a ground source multi-heat pump system.
Résumé
This paper presents the performance of a water-to-refrigerant type ground source multi-heat pump (GSHP) system installed in a school building in Korea. The evaluation of the performance has been conducted under the actual operating conditions of the GSHP system. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the capacity and the input power were evaluated for determining the performance of the GSHP system. The average cooling coefficient of performance (COP) of the heat pump was found to be 8.3 at 65% partial load condition, while the overall system COP was found to be 5.9. The average heating COP of the heat pump was found to be 5.1 at 45% partial load condition, while the overall system COP was found to be 4.2.
Documents disponibles
Format PDF
Pages : 6 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance evaluation under the actual operation condition of a ground source multi-heat pump system.
- Identifiant de la fiche : 30000482
- Langues : Anglais
- Source : 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 12/07/2010
Liens
Voir d'autres communications du même compte rendu (121)
Voir le compte rendu de la conférence
-
A study on steam compression heat pumps for air...
- Auteurs : IEA HPC, ENDO N., OZAKI K., YABE A.
- Date : 16/10/1995
- Langues : Anglais
- Source : Compression systems with natural working fluids. Applications, experience and developments. Workshop proceedings.
Voir la fiche
-
Commissioning, preventive maintenance, and trou...
- Auteurs : CANE R. L. D., GARNET J. M., SACHS H. M.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 annual Meeting, Honolulu, Hawaii. Volume 108, part 2 + CD-ROM.
Voir la fiche
-
GROUND-SOURCE HEAT PUMP DEMONSTRATION FOR COMME...
- Auteurs : FLEMING W. S., HUSE W.
- Date : 03/1991
- Langues : Anglais
- Source : IEA HPC Newsl. - vol. 9 - n. 1
Voir la fiche
-
Refroidisseur fonctionnant à l'aide d'une pompe...
- Auteurs : FUJITA T., MITA N., MORIYAMA T., et al.
- Date : 2001
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 2
Voir la fiche
-
North American monitoring of a hotel with room ...
- Auteurs : HENDERSON H. I., CARLSON S. W., WALBURGER A. C.
- Date : 17/06/1998
- Langues : Anglais
- Source : Heat pump systems for single-room applications. Workshop proceedings.
Voir la fiche