Résumé
This paper presents the results of comparing the suitability of six reported chiller performance models to be used for energy analysis. The data adopted to validate the models comprise of two broad classes including constant and variable chilled water flow rates. There are 373 sets of data in total. The optimal regression coefficient for each empirically based model is obtained by using the least square method. Criteria for evaluating the model suitability are based on the coefficient of variation of root-mean-square error (CVRMSE). The results show that among the six empirically based performance models for liquid chillers chosen in the study, the multivariate polynomial regression model possesses the best prediction accuracy. Its average CVRMSE value is around 0.66%. The results of the study could serve as a reference for the selection of empirically based models for liquid chillers when applied to the energy analysis of buildings.
Documents disponibles
Format PDF
Pages : pp. 641-646
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of the suitability of empirically based models for the prediction of energy performance of liquid chillers.
- Identifiant de la fiche : 2010-0874
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Date d'édition : 20/05/2009
Liens
Voir d'autres communications du même compte rendu (102)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Refroidisseurs d'eau
- Mots-clés : Logiciel; Comparaison; Refroidisseur; Simulation; Performance; Modélisation; Conditionnement d'air
-
Recent developments in the design of a new air-...
- Auteurs : CASTRO J., OLIVA A., PÉREZ-SEGARRA C. D., et al.
- Date : 19/01/2008
- Langues : Anglais
- Source : ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
Voir la fiche
-
Impact des conditions de fonctionnement réelles...
- Auteurs : WEI Y.
- Date : 08/2000
- Langues : Chinois
- Source : HV & AC - vol. 30 - n. 135
Voir la fiche
-
An air-conditioning model validation and implem...
- Auteurs : HADDAD K. H.
- Date : 2004
- Langues : Anglais
- Source : ASHRAE Transactions. 2004 Annual Meeting, Nashville, Tennessee, USA. Volume 110, part 2 + CD-ROM.
Voir la fiche
-
Evaluation of a small capacity, hot water drive...
- Auteurs : CASTRO J., OLIVA A., PÉREZ-SEGARRA C. D., et al.
- Date : 01/2007
- Langues : Anglais
- Source : HVAC&R Research - vol. 13 - n. 1
Voir la fiche
-
Evaluation of the design of chilled water syste...
- Auteurs : FANG X., JIN X., DU Z., et al.
- Date : 25/02/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 113