Evaluation des économies d'énergie d'un système de conditionnement d'air avec refroidissement à haute température et chauffage à basse température dans un bureau à Tokyo.
High-temperature cooling & low-temperature heating AC system evaluation of energy saving in an office in Tokyo.
Résumé
While the efficiency of water piping central AC systems has improved greatly, improving in the efficiency of the overall system had been a problem that needed to be solved. The High-Temperature Cooling & Low-Temperature Heating AC System (WATER EXCEL) centers on using a medium temp. refrigerant, having a large temp. difference between the inlet/outlet of a heat-exchanger, having low temp. air-blow, adjusting control of OA/RA volume at the chamber room and ensuring a radiant and laminar flow. A new specification has been established “10;10;13”. We took measurements in an office building in Tokyo for one year to evaluate the energy-saving properties and comfort of this system. New specification “(1)10;(2)10;(3)13” refers to reference temperatures for an energy transfer medium. (1) Cold water temperature is 10°C (improved heat source efficiency by shifting from the conventional 7°C to 10°C toward middle temperature). (2) Coil doorway difference of temperature is 10K. (reduction in pump power by having a larger temperature difference from 5K to 10K and water volume reduction). (3) Cooling air supply temperature is 13°C (reduction in blowing power by reducing air volume from the conventional 16°C)
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : High-temperature cooling & low-temperature heating AC system evaluation of energy saving in an office in Tokyo.
- Identifiant de la fiche : 30015446
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Date d'édition : 16/08/2015
- DOI : http://dx.doi.org/10.18462/iir.icr.2015.0732
Liens
Voir d'autres communications du même compte rendu (657)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Bureau; Japon; Immeuble; Basse température; Haute température; Économie d'energie; Conditionnement d'air; Chauffage
-
Two-pipe chilled beam system for both cooling a...
- Auteurs : AFSHARI A., NOROUZI R. G., HULTMARK G., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Energy performance of office buildings with low...
- Auteurs : PETRÁS D., BUGÁN J., KRAJCÍK M.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
A study on the integrated control system as an ...
- Auteurs : KANG K., PARK J., KANG G., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Current status of energy conservation refurbish...
- Auteurs : AOZASA K., AKIMOTO T., SATO T.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Impact of increase of the air ventilation rate ...
- Auteurs : ZMEUREANU R., et al.
- Date : 10/1992
- Langues : Anglais
Voir la fiche