Évaluation des frigorigènes alternatifs au R410A dans une pompe à chaleur réversible résidentielle air-eau.

Evaluation of R410A alternative refrigerants in a residential reversible air-to-water heat pump.

Auteurs : PARDO P.

Type d'article : Article

Résumé

Alternative refrigerants to R-410A are under investigation for residential heat pumps and air-conditioners since R-410A has a GWP of 2088. In this paper, two promising alternative refrigerants, DR-5A (R-454B) and L41-2 (R-447A), both HFC-HFO mixtures with a GWP of 466 and 583, respectively, have been tested in a residential heat pump. The results show that R-410A replacement by L41-2 and DR-5A does not raise any particular problems and the performance obtained is, aside from some few excep¬tions, almost equivalent (+/-10 %) to that with R-410A. These experimental results provide better under¬standing and knowledge about R-410A replacement in heat pumps.

Détails

  • Titre original : Evaluation of R410A alternative refrigerants in a residential reversible air-to-water heat pump.
  • Identifiant de la fiche : 30019744
  • Langues : Anglais
  • Source : IEA Heat Pump Centre Newsletter - vol. 34 - n. 1
  • Date d'édition : 2016

Liens


Voir d'autres articles du même numéro (4)
Voir la source