Evaluation of R410A alternative refrigerants in a residential reversible air-to-water heat pump.

Author(s) : PARDO P.

Type of article: Article

Summary

Alternative refrigerants to R-410A are under investigation for residential heat pumps and air-conditioners since R-410A has a GWP of 2088. In this paper, two promising alternative refrigerants, DR-5A (R-454B) and L41-2 (R-447A), both HFC-HFO mixtures with a GWP of 466 and 583, respectively, have been tested in a residential heat pump. The results show that R-410A replacement by L41-2 and DR-5A does not raise any particular problems and the performance obtained is, aside from some few excep¬tions, almost equivalent (+/-10 %) to that with R-410A. These experimental results provide better under¬standing and knowledge about R-410A replacement in heat pumps.

Details

  • Original title: Evaluation of R410A alternative refrigerants in a residential reversible air-to-water heat pump.
  • Record ID : 30019744
  • Languages: English
  • Source: IEA Heat Pump Centre Newsletter - vol. 34 - n. 1
  • Publication date: 2016

Links


See other articles in this issue (4)
See the source