Évaluation des performances d’un système de pompe à chaleur en cascade polyvalente pour un bâtiment résidentiel.
Performance evaluation of multi-functional cascade heat pump system for a residential building.
Numéro : 0585
Auteurs : KIM B. J., CHO H. J., LEE S. J., KWON T. D., JEONG J. W.
Résumé
With increasing fossil fuel usage in building air-conditioning systems, air-source heat-pump systems are in the spotlight as an alternative HVAC system to reduce carbon emissions. The aim of this study is to evaluate a multi-functional cascade heat pump system for a residential building. A design method suited in residential buildings was applied to evaluate system performance of the proposed system. A reference system as separate two heat pumps was selected in charge of cooling, heating and hot water supply. The target building was set to residential of 100m2, 5 occupants are in the building. The thermal load of the target building was derived with commercial transient simulation tool, thermodynamic equations, and model equations built-in EnergyPlus were used. As a result, the proposed system saves 13% energy in cooling mode and 10% in heating mode compared with the reference system. The energy saving effect was occurred at the compression ratio of each high- and low-cycle decreasing due to the effect of recovering unused waste heat in summer and increasing the temperature of the refrigerant in winter.
Documents disponibles
Format PDF
Pages : 8
Disponible
Gratuit
Détails
- Titre original : Performance evaluation of multi-functional cascade heat pump system for a residential building.
- Identifiant de la fiche : 30033278
- Langues : Anglais
- Source : 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Date d'édition : 05/2023
Liens
Voir d'autres communications du même compte rendu (166)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Pompes à chaleur à usage domestique
- Mots-clés : Pompe à chaleur; Secteur résidentiel; Performance; Modélisation
-
Generalized performance maps for single and dua...
- Auteurs : NYIKA S., HOLLOWAY S., BRAUN J. E., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Review of heat pump tumble clothes dryer energy...
- Auteurs : GRABAN A. R., GROLL E. A., BRAUN J. E., ZIVIANI D.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Field measurements of ground source heat pump s...
- Auteurs : HAGLUND STIGNOR C., TILJANDER P., ALSBJER M.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Empirical platform data analysis to investigate...
- Auteurs : CARMO C., ELMEGAARD B., NIELSEN M. P., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
ICE-MAKER HEAT PUMP HARVESTING SCHEME DEVELOPME...
- Auteurs : BAXTER V. D.
- Date : 1981
- Langues : Anglais
Voir la fiche