Evaluation du confort thermique d'un environnement thermique non homogène créé par un système de conditionnement d'air utilisant une sortie d'air au sol.
[In Japanese. / En japonais.]
Auteurs : NAKAMURA Y., FUJIKAWA A., UENO O., et al.
Type d'article : Article
Résumé
Subjective experiments were carried out to evaluate the thermal comfort of a nonhomogeneous thermal environment created in a task area using floor air outlet. Subjects are allowed to control freely the air volume supply from the floor air outlet and the angle of elevation of the central axis of the jet from the floor outlet to get their thermal comfort. The remote control of the air volume supply and the angle of elevation are easily done using controllers on the desks. Various combinations of the air volume supply and the angle of elevation of the air jets were selected by subjects to achieve their thermal comfort, and then it was found that the comfortable conditions selected by subjects are well explained by SET; that is, most of the selected conditions are included in the range of 24-26 °C of SET. Concerning the impression for air movement, most of the subjects accept the air movement as a desirable thermal factor without feeling the cold draft. It is also found that an increase in the air volume supply from the floor air outlet does not contribute to a decrease in the air temperature in the task area but increases the coolness by increasing air velocity in the task area.
Détails
- Titre original : [In Japanese. / En japonais.]
- Identifiant de la fiche : 2004-1867
- Langues : Japonais
- Source : Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 92
- Date d'édition : 01/2004
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (3)
Voir la source
Indexation
-
Simplified model for desired airflow rate in un...
- Auteurs : ZHANG K., ZHANG X., LI X.
- Date : 25/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
Voir la fiche
-
The effect of partial body cooling on entire bo...
- Auteurs : FUKAGAWA R., KURAZUMI Y., KITAYAMA H., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Work environment thermal evaluation with underf...
- Auteurs : LEITE B. C. C., TRIBESS A., ORNSTEIN S. W.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
Chilled beams and UFAD: an energy-efficient team.
- Auteurs : STRAPP P.
- Date : 05/2012
- Langues : Anglais
- Source : HPAC Engineering - vol. 84 - n. 5
Voir la fiche
-
Underfloor for schools.
- Auteurs : MEGERSON J. E., LARSON C. R.
- Date : 05/2008
- Langues : Anglais
- Source : ASHRAE Journal - vol. 50 - n. 5
Voir la fiche