Evaluation du GPL en tant que frigorigène naturel pour les conditionneurs d'air domestiques.

Assessment of LPG as a natural refrigerant for domestic air conditioners.

Auteurs : AWAD M. el-

Type d'article : Article

Résumé

This study investigates the use of liquefied petroleum gas (LPG) as an alternative natural refrigerant to R22. A computer model that compares the performance of propane-butane mixture as refrigerants with that of conventional synthetic refrigerants has been developed. In the present study, the model is used to compare LPG with R22 on the basis of 1.0 kilowatt of refrigeration capacity and different values of the evaporating and condensing temperatures. The paper also reports the results of an experimental test in which R22 was replaced with LPG in a window air conditioner. The test showed that the performance of LPG was comparable to that of R22, but it gives a higher temperature at the compressor discharge.

Documents disponibles

Format PDF

Pages : 33-41

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Assessment of LPG as a natural refrigerant for domestic air conditioners.
  • Identifiant de la fiche : 2005-0370
  • Langues : Anglais
  • Source : RACA Journal - vol. 20 - n. 5
  • Date d'édition : 07/2004