Évaluation du recours au refroidissement photovoltaïque dans un centre de données.
Evaluation of photovoltaic cooling application to a data center.
Numéro : pap. n. 71
Auteurs : BELIZARIO A., SIMÕES-MOREIRA J. R.
Résumé
Nowadays, data processing is a fundamental operation for business such as banks, among others. However, computers dissipate heat and as the operating temperature increases and these machines cannot operate properly. Consequently, it is necessary to air conditioning systems to keep the proper temperature as well as the room temperature itself. Therefore, a data center air conditioning system drains electrical energy in the installation. Based on this, this paper evaluates a photovoltaic cooling to support the electric chiller system showing the energy saving. The case is analyzed in a Data Center located in São Paulo, Brazil. The electrical power density consumed by the computers is 0.5, 1.0, 2.0, 4.0 and 8.0 kW/m2. Local solar irradiation indexes are based on the ASHRAE Data Bases temperature. The results represent a 22%, 12%, 13%, 5% and 3% of energy savings, respectively
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of photovoltaic cooling application to a data center.
- Identifiant de la fiche : 30026219
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0071
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
-
Evaluation of the heat and energy performance o...
- Auteurs : SANTOS A. F. dos, SOUZA H. J. L. de, GASPAR P. D.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Worldwide electricity used in data centers.
- Auteurs : KOOMEY J. G.
- Date : 2008
- Langues : Anglais
- Source : Environmental research letters - n. 3
Voir la fiche
-
Applications of absorption chillers.
- Auteurs : BARBERIS F.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Application of a systematic approach to evaluat...
- Auteurs : HAUSSER S., HUDJETZ S., BECKER M.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Dossier : la clim dans l'industrie.
- Date : 03/2006
- Langues : Français
- Source : CLIM Prat. - n. 77
Voir la fiche