Évaluation des performances énergétique et de chaleur d’un centre de données en utilisant un nouvel indice d’efficacité : l’efficacité de l’utilisation de l’énergie - EUE.
Evaluation of the heat and energy performance of a data center by a new efficiency index: energy usage effectiveness design - EUED.
Numéro : pap. n. 885
Auteurs : SANTOS A. F. dos, SOUZA H. J. L. de, GASPAR P. D.
Résumé
Data Centers are growing steadily worldwide and they are expected to continue on growing up to 53% in 2020. Due to this growth the energy efficiency in this type of building is essential. There are methodologies to measure this efficiency; one example is PUE (Power Usage Effectiveness). The unit suggested for measuring efficiency at the design stage would be the EUED (Energy Usage Efficiency Design) with this will be used data to use "free cooling" and adiabatic system in some cases, a comparison will be made only considering the equipment in the worst situation. It also uses the study of enthalpy utilization as a new methodology to obtain the results. By doing so, differences were found, between cities than 1.21% of São Paulo in relation to Curitiba and 10.61% of Rio de Janeiro in relation to Curitiba. The indices obtained by applying the EUED index were 1.245 kW.kW-1 for Curitiba, 1.260 kW.kW-1 for São Paulo and 1.377 kW.kW-1 for Rio de Janeiro, respectively, giving a difference of 16.86% for Curitiba of 16.19% for São Paulo and 10.31% for Rio de Janeiro in relation to PUE COA (Power Usage Effectiveness Constant Outdoor Air).
Documents disponibles
Format PDF
Pages : 8
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Evaluation of the heat and energy performance of a data center by a new efficiency index: energy usage effectiveness design - EUED.
- Identifiant de la fiche : 30026663
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Date d'édition : 24/08/2019
- DOI : http://dx.doi.org/10.18462/iir.icr.2019.0885
Liens
Voir d'autres communications du même compte rendu (632)
Voir le compte rendu de la conférence
-
Optimizing data center energy consumption.
- Auteurs : PURKAYASTHA I.
- Date : 27/07/2018
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
Voir la fiche
-
Koeltechnologieën voor zeer energieefficiënte d...
- Auteurs : BERENDS E.
- Date : 02/2012
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 105
Voir la fiche
-
Airside economizers in data centers.
- Auteurs : BEATY D. L.
- Date : 01/2015
- Langues : Anglais
- Source : ASHRAE Journal - vol. 57 - n. 1
Voir la fiche
-
Keeping your cool in server rooms.
- Auteurs : WALLACE D.
- Date : 12/2014
- Langues : Anglais
- Source : Climate Control News
Voir la fiche
-
Integrated system of mechanical refrigeration a...
- Auteurs : ZHANG H., SHAO S., XU H., et al.
- Date : 01/2015
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 75
Voir la fiche