Document IIF

Evaluation expérimentale d’un appareil utilisé pour des essais sur un régénérateur magnétique alternatif linéaire à base de gadolinium.

Experimental evaluation of a Gd-based linear reciprocating active magnetic regenerator test apparatus.

Auteurs : TREVIZOLI P. V., BARBOSA J. R. Jr, FERREIRA R. T. S.

Type d'article : Article, Article de la RIF

Résumé

The present paper describes the design, operation and preliminary results of an active magnetic regenerator test machine. The regenerator consists of twenty eight 0.85 mm thick parallel gadolinium (Gd) plates that form 0.1 mm thick parallel channels with an effective length of 126 mm. The working fluid is water and the magnetic field source is a Halbach array with a maximum flux density of 1.65 T. A maximum temperature span between the hot and cold ends of the regenerator (?TREG) of 4.45 K and a maximum cooling capacity of 3.9 W were measured in tests without and with a thermal load, respectively. The behavior of ?TREG as a function of the utilization factor and of the temperature of the hot source is explored in the manuscript. The experimental results are discussed in the light of the fluid flow and heat transfer phenomena taking place in the regenerator.

Documents disponibles

Format PDF

Pages : 1518-1526

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental evaluation of a Gd-based linear reciprocating active magnetic regenerator test apparatus.
  • Identifiant de la fiche : 30001540
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 6
  • Date d'édition : 09/2011

Liens


Voir d'autres articles du même numéro (20)
Voir la source