Document IIF

Evaluation expérimentale d'un chauffe-eau utilisant du CO2.

Experimental evaluation of CO2 water heater.

Résumé

The paper presents experimental results of the CO2 cycle for the tap-water heating application. A laboratory prototype of CO2 cycle with hermetic compressor was built. After optimizing the refrigerant charge and metering valve opening, the gas cooler side water flow rate and tap-water temperature were varied as an experimental parametric study. The performance of CO2 was compared with that of R22. CO2 has 10% higher capacity and COP than R22 over the various ambient temperatures.

Documents disponibles

Format PDF

Pages : 1998-4

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental evaluation of CO2 water heater.
  • Identifiant de la fiche : 1999-2797
  • Langues : Anglais
  • Source : Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
  • Date d'édition : 02/06/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (65)
Voir le compte rendu de la conférence