Résumé

The successful use of CO2 as a refrigerant on a large scale and its introduction to new applications requires the development of system components, including reliable, low-cost refrigeration fittings. Press fittings are an attractive option, because this connection type does not require an open flame, is easy to establish, and is suitable for field maintenance. However, the use of R744 exposes this fitting type to challenges that are characteristic to CO2 only. This paper reports the research conducted to explore the suitability of this new fitting type for use with CO2, including new test methods to study explosive decompression characteristics of its O-ring materials and the ability of the fittings’ stainless steel body to withstand exposure to carbonic and activated acids. The results show that the sealing ability of the tested fittings is not compromised by explosive decompression or exposure to carbonic and activated acids.

Documents disponibles

Format PDF

Pages : 8

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental evaluation of flame-free refrigerant fittings according test criteria specific to R744.
  • Identifiant de la fiche : 30023507
  • Langues : Anglais
  • Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
  • Date d'édition : 18/06/2018
  • DOI : http://dx.doi.org/10.18462/iir.gl.2018.1142

Liens


Voir d'autres communications du même compte rendu (177)
Voir le compte rendu de la conférence