Document IIF
Évaluation expérimentale du R-472B comme substitut au R-23 pour le froid à ultra-basse température.
Experimental evaluation of R472B as R23 alternative for ultra-low temperature refrigeration.
Numéro : 1156
Auteurs : GIMÉNEZ-PRADES P., MAIORINO A., APREA C., NAVARRO-ESBRÍ J., UDROIU C-M., FORÉS-PALANQUES A., MOTA-BABILONI A.
Résumé
This work experimentally assesses R472B as a lower-GWP alternative to R23 in a two-stage cascade ultra-low temperature refrigeration system. First, the pull-down performance from 15, 20 and 25 °C down to –70 °C is analysed. Then, the hysteresis operation with set freezer temperatures of –70, –60, and –50 °C is studied. The pull-down time was higher for R472B compared to R23, with a time difference from 23 to 40 minutes. Regarding the hysteresis operation, the lowest energy consumption for all the tested conditions was achieved by R472B, being 8.4 to 17.5% lower than R23. The cooling capacity of R472B was 9.4 to 26% lower at –70 and –60 °C, and up to 13% higher at –50 °C. COP was comparable at –70 and –60 °C, and at –50 °C, R472B COP was up to 15.6% higher. The environmental analysis of the hysteresis operation shows that equivalent CO2 emissions can be reduced by 65% when using R472B instead of R23.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental evaluation of R472B as R23 alternative for ultra-low temperature refrigeration.
- Identifiant de la fiche : 30034191
- Langues : Anglais
- Sujet : Technologie
- Source : 1st IIR International Conference on Refrigeration Adapting to Rising Temperatures
- Date d'édition : 08/2025
- DOI : http://dx.doi.org/10.18462/iir.adaptation.2024.1156
Liens
Voir d'autres communications du même compte rendu (45)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Physique à basse température;
Mélanges - Mots-clés : Basse température; Application médicale; Consommation d'énergie; Faible GWP; R23; R472B
-
Experimental investigation on a Joule-Thomson r...
- Auteurs : ZOU L., YU M., BAI T., QIAN S., YU J.
- Date : 11/06/2024
- Langues : Anglais
- Source : 8th IIR International Conference on Sustainability and the Cold Chain. Proceedings: June 9-11 2024
- Formats : PDF
Voir la fiche
-
Advances in large scale applications of superco...
- Auteurs : KOMAREK P.
- Date : 2000
- Langues : Anglais
- Source : Applied superconductivity 1999. 1. Large-scale applications. 2. Electronic applications.
Voir la fiche
-
Recent R&D status on 70 MW class superconductin...
- Auteurs : AGETA T.
- Date : 2000
- Langues : Anglais
- Source : Applied superconductivity 1999. 1. Large-scale applications. 2. Electronic applications.
Voir la fiche
-
Refrigerant replacement from HFC to HC in a med...
- Auteurs : HENSE D., KARNOPP J.
- Date : 2022
- Langues : Anglais
- Source : 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Fibre composite structures for space applicatio...
- Auteurs : BANSEMIR H., HAIDER O.
- Date : 01/1998
- Langues : Anglais
Voir la fiche