Évaluation thermo-économique d'un climatiseur utilisant le refroidissement évaporatif direct : analyse approfondie.

Thermo-economic assessment of air conditioner utilizing direct evaporative cooling: A comprehensive analysis.

Auteurs : GUPTA S. K., ARORA B. B., ARORA A.

Type d'article : Article de la RIF

Résumé

As concerns regarding energy consumption and environmental impact continue to grow, the need for efficient and sustainable cooling technologies becomes increasingly significant. Among various alternatives, direct evaporative cooling (DEC) has emerged as a promising solution due to its energy-efficient operation and low environmental footprint. This paper aims to provide a comprehensive thermo-economic assessment of a 5.25 kW capacity split air conditioner (SAC) integrated with direct evaporative cooling, focusing on evaluating its performance, energy consumption, coefficient of performance, and economic viability. A numerical model is developed to determine the reduction in the condenser inlet air temperature due to direct evaporative cooling. The ambient temperature (30–45 ⁰C), relative humidity (20–80 %), and evaporator temperature (3–12 ⁰C) are taken as the design variables. Box–Behnken design (BBD) technique of response surface methodology is applied for multi-objective optimization. The , total cost rate , and total exergy destruction ( are set as the objective functions. Cooling capacity, life period, operation time, interest rate, maintenance factor, and electricity cost are taken as constants. The thermoeconomic optimization evolved maximized enhancement of 68.94 %, and reduction in TCR and by 26.12 % and 57.23 %, respectively. The water consumption to energy saving ratio varies from 5.5 to 9.8 L/kWh for different months of the cooling season. The thermoeconomic performance and sustainability of DECSAC is observed to significantly improve compared to conventional SAC specifically in hot-dry climates. The simple payback of the proposed system ranges between 1.21 to 2.99 years depending upon the operating conditions.

Documents disponibles

Format PDF

Pages : 68-88

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Thermo-economic assessment of air conditioner utilizing direct evaporative cooling: A comprehensive analysis.
  • Identifiant de la fiche : 30032114
  • Langues : Anglais
  • Sujet : Technologie
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 158
  • Date d'édition : 02/2024
  • DOI : http://dx.doi.org/10.1016/j.ijrefrig.2023.11.021

Liens


Voir d'autres articles du même numéro (36)
Voir la source