Document IIF
Évaluer la performance exergétique des systèmes de pompe à chaleur sans utilisation des propriétés thermodynamiques du frigorigène.
Assessing the exergy performance of heat pump systems without using refrigerant thermodynamic properties.
Auteurs : SALOUX E., SORIN M., TEYSSEDOU A.
Type d'article : Article, Article de la RIF
Résumé
This paper tackles the assessment of the exergy performance of heat pumps. This work is based on a modeling that does not require the evaluation of refrigerant thermodynamic properties and is applied to two commercial (water–water and air–air types) units for various operating conditions (i.e., temperatures at the inlet side of the evaporator and the condenser). The total exergy destruction and the irreversibility distribution into the components are estimated and cover a broad range of values. As well, the nature of the sources of exergy destruction, divided into non-renewable (electrical) and renewable (thermal) energy flows, is also investigated. This distribution, which allows the use of electricity that is really paid by the user to be clearly identified, provides different optimal operating conditions, as compared with the total exergy destruction. Finally, the influence of the exergy reference state temperature (either constant or variable) is examined; in particular, with the air–air heat pump that permits the space heating demand of a building to be achieved. Although the effect on the exergy destruction is relatively low, varying the exergy reference state temperature strongly affects the exergy efficiency, which then appears to appropriately evaluate the use of energy in heat pumps.
Documents disponibles
Format PDF
Pages : 1-9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Assessing the exergy performance of heat pump systems without using refrigerant thermodynamic properties.
- Identifiant de la fiche : 30024626
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 93
- Date d'édition : 09/2018
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2018.06.005
Liens
Voir d'autres articles du même numéro (25)
Voir la source
Indexation
- Thèmes : Techniques des pompes à chaleur
- Mots-clés : Exergie; Application commerciale; Air-air; Pompe à chaleur; Performance; Modélisation; Eau-eau
-
Simulation of a unitary water source heat pump.
- Auteurs : CHEN Z., HE Y.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche
-
Modeliranje i simulacija toplotnih pumpi voda-v...
- Auteurs : KALOJANOV N., STOICKOV N.
- Date : 02/2004
- Langues : Serbe
- Source : KGH (Klimatizacija Grejanje Hladenje) - vol. 33 - n. 1
Voir la fiche
-
A parameter estimation based model of water-to-...
- Auteurs : JIN H., SPITLER J. D.
- Date : 2002
- Langues : Anglais
- Source : ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
Voir la fiche
-
Optimized design of a heat exchanger for an air...
- Auteurs : BLANCO CASTRO J., URCHUEGUÍA J. F., CORBERÁN J. M., et al.
- Date : 10/2005
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 25 - n. 14-15
Voir la fiche
-
Study on the condensing heat recovery optimum m...
- Auteurs : ZHOU E. Z., FAN B., DONG H.
- Date : 05/04/2008
- Langues : Anglais
- Source : Cryogenics and refrigeration. Proceedings of ICCR'2008.
Voir la fiche