Document IIF
Évaporation de l’ammoniac à détente directe côté calandre sur un faisceau de tubes plats avec effet de surchauffe en sortie.
Shell side direct expansion evaporation of ammonia on a plain tube bundle with exit superheat effect.
Auteurs : AYUB Z. H., ABBAS A., AYUB A. H., et al.
Type d'article : Article, Article de la RIF
Résumé
There are no data available on the direct expansion evaporation of refrigerant on the outside of a tube bundle.With the current ozone depletion and global warming issues it is critical to develop systems with low charge refrigerants especially with natural refrigerants such as ammonia which has zero ozone depletion potential (ODP) and zero global warming potential (GWP). This study presents results of an extensive experimental work on direct expansion of ammonia on a triangular pitch plain tube bundle with saturation temperature range -1.7 to -20 °C, heat flux range 5 to 45 kW m-2 and exit superheat range 2 to 10 °C. The test matrix falls well within the practical operating conditions of industrial refrigeration systems. A typical increase in heat transfer coefficient was observed with saturation temperature and heat flux. The effect of exit super heat on the overall performance of the bundle was also reported. A correlation for outside boiling on a tube bundle in direct expansion mode was developed and compared with existing single tube pool, flooded bundle boiling and spray evaporation studies.
Documents disponibles
Format PDF
Pages : 126-135
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Shell side direct expansion evaporation of ammonia on a plain tube bundle with exit superheat effect.
- Identifiant de la fiche : 30022240
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 76
- Date d'édition : 04/2017
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2017.02.001
Liens
Voir d'autres articles du même numéro (33)
Voir la source
Indexation
-
Thèmes :
Transfert de chaleur;
Ammoniac - Mots-clés : Ébullition libre; Sécurité; Détente directe; Réfrigeration; R717; Surchauffe; Experimentation; Échangeur multitubulaire
-
Comparison of a conventional flooded evaporator...
- Auteurs : ABBAS A., AYUB Z., AYUB A., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Shell side direct expansion evaporation of ammo...
- Auteurs : SHAH W., ABBAS A., AYUB Z. H., AYUB A. H., MOREIRA T. A., RIBATSKI G., LI W.
- Date : 03/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 147
- Formats : PDF
Voir la fiche
-
Shell side direct expansion evaporation of ammo...
- Auteurs : ABBAS A., AYUB Z. H., AYUB A. H., et al.
- Date : 10/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
Voir la fiche
-
Experimental study on falling film evaporation ...
- Auteurs : AKADA I., OBATA K., KATO M., et al.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Experimental pool boiling heat transfer coeffic...
- Auteurs : PRADO J. I., FERNÁNDEZ-SEARA J., VALLEJO J. P., et al.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche