Résumé
Implementation of CO2 in North American supermarkets is currently in its infancy. Since 2006, several systems utilizing CO2 as a low-temperature two-phase secondary coolant have been installed and started in various supermarket sizes and formats, with several more installations in progress. Significant practical information has been gained through start-up and operation of these systems relating to performance, maintenance, safety, energy consumption, and refrigerant charge. Customer experiences are presented, along with field comparisons indicating energy parity with conventional HFC systems. Low-temperature CO2 secondary coolant systems are most often installed in conjunction with medium-temperature secondary systems using propylene glycol; resulting impacts on refrigerant charge, leakage rates, and TEWI effects are discussed. The results of a detailed analysis of the distribution piping network is presented which focuses on impacts of material costs and piping heat gain compared to conventional direct expansion systems using HFC refrigerants. A final discussion of the future potential of CO2 systems in North America is also included.
Documents disponibles
Format PDF
Pages : 2008-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2 experiences in North American supermarkets.
- Identifiant de la fiche : 2009-0650
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Date d'édition : 07/09/2008
Liens
Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente;
Frigoporteurs liquides - Mots-clés : Système frigorifique; Amérique du nord; Supermarché; Étude de cas; Frigoporteur; CO2
-
Carbon dioxide in North American supermarkets.
- Auteurs : HINDE D., ZHA S., LAN L.
- Date : 02/2009
- Langues : Anglais
- Source : ASHRAE Journal - vol. 51 - n. 2
Voir la fiche
-
Réalisation d'un supermarché avec système CO2 i...
- Auteurs : GOETZ J.
- Date : 21/09/2006
- Langues : Français
- Source : Nouveaux fluides : confinement ; réglementation. Colloque effet de serre V.
Voir la fiche
-
Veel voordelen natuurlijke koudemiddelen: Bort ...
- Date : 04/2004
- Langues : Néerlandais
- Source : Koude & Luchtbehandeling - vol. 97 - n. 4
Voir la fiche
-
Using CO2 in supermarkets.
- Auteurs : PEARSON A., CAMPBELL A.
- Date : 02/2010
- Langues : Anglais
- Source : ASHRAE Journal - vol. 52 - n. 2
Voir la fiche
-
Safety of CO2 in large refrigeration systems.
- Auteurs : GTZ Proklima, SAWALHA S.
- Date : 07/2008
- Langues : Anglais
Voir la fiche