Résumé
CO2 has been recognized as an ideal refrigerant for the low-temperature cycle (LTC) in a commercial cascade refrigeration system (CRS). Against the backdrop of global warming, low-GWP refrigerant substitution for the high-temperature cycle (HTC) is becoming increasingly critical, and R515B is regarded as a promising solution. In this paper, an R515B/CO2 CRS experimental setup is constructed to comprehensively evaluate the system performance under various operating conditions. Moreover, performance variations of the refrigeration compressors in the LTC and HTC are also tested and analyzed. According to the results, the LTC performance is primarily governed by the intermediate and evaporating temperatures, remaining relatively insensitive to the condensing temperature. In contrast, the HTC performance exhibits high sensitivity to the condensing temperature. Consequently, increasing the condensing temperature substantially raises the power consumption of the HTC compressor and leads to a marked decline in the system coefficient of performance (COPsys). The analysis also confirms the existence of an optimal intermediate temperature. Under typical operating conditions with a condensing temperature of 40◦C and an evaporating temperature of -23◦C, the system achieves a maximum COPsys of 1.74. Furthermore, the R515B/CO2 system demonstrates superior thermodynamic performance compared to similar CRSs utilizing high-GWP refrigerants as reported in the literature. Specifically, at an evaporating temperature of -30◦C and a condensing temperature of 40◦C, the system achieves a COPsys of 1.48, representing an improvement of approximately 4.2% over the best-reported R134a/CO2 CRS under identical conditions. From a life-cycle environmental perspective, the total equivalent warming impact of the R515B/CO2 CRS is also reduced by approximately 15.0% compared to the R134a/CO2 CRS. Coupled with its A1 safety classification and low GWP, R515B proves to be a highly promising HTC refrigerant for commercial CRSs.
Documents disponibles
Format PDF
Pages : 11 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental study of an R515B/CO2 cascade refrigeration system for commercial applications.
- Identifiant de la fiche : 30034900
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 186
- Date d'édition : 06/2026
- DOI : http://dx.doi.org/https://doi.org/10.1016/j.ijrefrig.2026.106901
Liens
Voir d'autres articles du même numéro (27)
Voir la source
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente;
HFC;
Mélanges - Mots-clés : Faible GWP; R744; R515B; HFC; Mélange; Système en cascade; Experimentation; Variation de température
-
Recherche expérimentale sur un système frigorif...
- Auteurs : SHEN J., HU B., QIU J., et al.
- Date : 08/2013
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 34 - n. 152
- Formats : PDF
Voir la fiche
-
Halb natürlich, halb synthetisch: CO2-Kaskadent...
- Auteurs : WIRSCHING A.
- Date : 05/02/2010
- Langues : Allemand
- Source : CCI Zeitung - vol. 44 - n. 02
- Formats : PDF
Voir la fiche
-
Una "cascata" di NH3/CO2.
- Auteurs : SAWALHA S., PERALES CABREJAS C., LIKITTHAMMANIT M., et al.
- Date : 04/2009
- Langues : Italien
- Source : Bull. IIF-IIR/Freddo - vol. 63 - n. 2
Voir la fiche
-
Une cascade R404A/CO2 pour froid positif et nég...
- Auteurs : LE MERCIER P.
- Date : 03/2010
- Langues : Français
- Source : La revue pratique du froid et du conditionnement d'air - n. 983
Voir la fiche
-
Cooling supermarkets the eco-friendly way.
- Date : 09/2008
- Langues : Anglais
- Source : Air Conditioning and Refrigeration Journal, Cold Chain - vol. 22 - n. 5
- Formats : PDF
Voir la fiche