Résumé
A primary reason R-404A has become the preferred refrigerant for commercial refrigeration over the last two decades is its low compressor discharge temperature which provides excellent protection for compressors and significantly improves their operability and durability. However, R-404A is also one of the highest GWP refrigerants in use today and has been targeted by various regulatory agencies for potential phase-down or phaseout. Several reduced GWP options have been proposed using blends of HFCs and hydrofluoroolefins (HFOs) that are around 1300 GWP. However, these blends have increased compressor discharge temperature and in some applications may require external compressor cooling. A new non-flammable refrigerant DR-34 has been developed with low compressor discharge temperature similar to R-404A and closely matches all other properties and performance. This refrigerant will be particularly suitable for transport refrigeration where compressor cooling is difficult to manage under a wide range of ambient conditions. This paper describes experimental testing in both truck and trailer transport refrigeration systems. Results demonstrate cooling capacity, energy efficiency, mass flow and compressor discharge temperature are comparable to R-404A. Miscibility of DR-34 is also measured with a polyol ester lubricant.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : R-404A alternative with low compressor discharge temperature.
- Identifiant de la fiche : 30012960
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 14/07/2014
Liens
Voir d'autres communications du même compte rendu (203)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Compresseurs;
HFC;
Mélanges;
Efficacité energétique, économie d'énergie - Mots-clés : Température; Refoulement; R404A; Substitut; Performance; GWP; Experimentation; Frigorigène; Compresseur
-
Low GWP replacements for R404A in commercial re...
- Auteurs : YANA MOTTA S., POTTKER G., SPATZ M., et al.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche
-
Low global warming refrigerants for commercial ...
- Auteurs : YANA MOTTA S., SPATZ M. W., VERA BECERRA E.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental assessment of R134a and its lower ...
- Auteurs : MOTA BABILONI A., MAKHNATCH P., KHODABANDEH R., et al.
- Date : 02/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
Voir la fiche
-
Mezclas HFC/HFO para sustituir al R404A en refr...
- Auteurs : MOTA BABILONI A., BARRAGÁN-CERVERA A., NAVARRO-ESBRÍ J., et al.
- Date : 03/05/2016
- Langues : Espagnol
- Source : CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
Voir la fiche
-
Analysis of the performance characteristics of ...
- Auteurs : GIL B.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche