Résumé
Environmental concerns raised by high global warming potential (GWP) refrigerants have triggered a series of activities around the world to curtail the use of hydrofluorocarbons (HFCs). Many of the promising alternative refrigerants being investigated are mildly flammable and fall under the A2L safety classification of ASHRAE 34. In an effort to properly address A2L refrigerants in safety standards, the Air-Conditioning, Heating, and Refrigeration Technology Institute (AHRTI) undertook a research project to investigate refrigerant leaks and ignition testing under whole scale room conditions. This paper summarizes refrigerant leak and ignition tests for A2L refrigerants R-32, R-452B, R-455A and R-457A. The work included two main tasks. The first involved testing R32 and R452B under a controlled environment to explore factors affecting the refrigerants’ ignition. These factors include refrigerant leak rates, leak locations, leak opening size and oil effect. In the second task, tests were conducted under whole room scale for typical air-conditioning and refrigeration configurations. The whole room testing simulated large refrigerant leaks with ignition sources present from a packaged terminal unit, a residential split AC, a rooftop unit, a reach-in cooler and a walk-in cooler under various scenarios. Key observations will be summarized and future research work will be discussed.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A2L refrigerants leaks and ignitions testing under whole room scale.
- Identifiant de la fiche : 30024411
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (252)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Mélanges;
Confinement, réduction de la charge en frigorigène - Mots-clés : Rate; R455A; R452B; R32; Inflammabilité; Experimentation; Fuite; Conditionnement d'air; Chambre d'essai
-
Numerical method on predicting distribution of ...
- Auteurs : HATTORI K., FUKUOKA M., MURATA M., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Méthode numérique pour prévoir la répartition d...
- Auteurs : HATTORI K., FUKUOKA M., TOMIOKA K., et al.
- Date : 2016
- Langues : Japonais
- Source : Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 33 - n. 2
Voir la fiche
-
Evaluation of leak detectors for flammable refr...
- Auteurs : ZHENG J., ELBEL S.
- Date : 05/2021
- Langues : Anglais
- Source : 2021 Purdue Conferences. 18th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Risk assessment of catastrophic leak of R452B f...
- Auteurs : ELATAR A., ABU-HEIBA A., PATEL V., et al.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Assessment of leakage rate and durability of fi...
- Auteurs : ELBEL S., LAWRENCE L., RAJ S.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche